Embracing Challenge

ƒ

ƒ

Sure detection even of minimal liquid
quantities

ƒ

ƒ

line break monitoring for LA 1S and LA
25S

ƒ

ƒ

Integrable in M&C-Universal filters and
flow chambers

ƒ

ƒ

Also versions for higher pressure and
temperatures

ƒ

ƒ

No electrolytic effects on the sensor
surface

ƒ

ƒ

High chemical resistance

ƒ

ƒ

Cable length up to 100 meters

Special Features

Liquid alarm sensors series LA®
for conductive media

Version LA 1S, LA 25S and flow chambers LS, LS 25 as well as
LA 1 and LA 25 for use in hazardous aereas

LA 1S

Application

Liquid alarm sensors are used in gas sam-

ple conditioning systems for monitoring gas

cooling and condensate drain-off devices in

order to provide protection for downstream

analysis instruments. This simple monitoring

device reliably signals the penetration of con-

densate in the event of cooling or condensate

drain-off equipment being defective and thus

avoids expensive down times as well as high

repair costs for analysis instruments.
In the event of alarm, the power for the

sample gas pump or a solenoid valve is to be

switched off in the gas sample conditioning

system.

Description

The M&C liquid sensors LA..S works on the

principle of electrical conductivity from 50

µS/cm conductance. In order to avoid electro-

lytic effects on the sensor surface, the sensors

are powered with alternating current.
The required electronic controller LA-1.. is

available in various versions and is described

in the separate data sheet 5-5.1.2.
Only the newly developed electronic con-

trollers as described in the afore mentioned

data sheet from date of construction 04/2006

onwards can be used for the M&C liquid sen-

sors LA..S.
The M&C LA..S liquid sensors are constructed

in such a way that any droplets of liquid in the

sample gas are attracted under gravity to the

sensor surface and even the smallest liquid

droplets trigger a sure and rapid alarm.
The LA 1S sensor is defined for operating

pressure up to 4 bar and LA 25S for up to 25

bar. The sensor protection corresponds to

type IP65 EN 60529.
The LA 1S sensor with its 12 mm diameter

glass body is mounted in the GL connection

of a F..-..-D universal filter or in the LS flow

chamber.

The LA 25S sensor has got a 1/4» spe-

cial male connector for mounting in the

FSS..-D universal filter or for mounting in

8 mm tubes using a special union tee con-

nector LS 25.
When mounting the universal filters and the

flow chamber, the gas inlet and gas outlets

can be rotated through 180° during assembly.
For hazardous areas the sensors LA 1 and LA

25 of the former series without line break

monitoring can be used because they are

«simple components». However the sensors

than may only be used with certified control

electronics, e.g. ER142 Exi (part no. 03E2009

for 230V or 03E2009a for 115V) for intrinsically

safe supply of the sensors.