MSD 7530T Programmable Digital-7 Ignition Control Installation User Manual

Page 10

Advertising
background image

10

INSTALLATION INSTRUCTIONS

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

SHIFT LIGHT

This program lets you select the number of gears (Last Gear), program the shift light to come on

when the holeshot rpm is reached, set an rpm point for each gear and the rpm drop for the ignition

to recognize as a gear shift between each gear. When the correct rpm is reached the Yellow wire is

switched to ground to turn the shift light on.

LAUNCH LIGHT

This programs an rpm window that will illuminate the shift light when the correct rpm is reached for

the holeshot. When the rpm is in this window the light will be on solid. If the rpm goes high, the light

will flash. If the rpm goes low, the light turns off.

RpmHi: The high rpm for the launch light program.

RpmLo: The low rpm for the launch light program.

ShiftLight: Program the rpm point for each gear change.

(1)Rpm

First gear rpm point to shift.

(2)Rpm

Second gear rpm point to shift.

(3-5 gears)

ShiftGear: Program the rpm drop between each gear that the ignition must see to recognize

a shift. Programmable from 200-1500 rpm.

(1)DropRpm

Rpm drop between first and second.

(2)DropRpm

Rpm drop between second and third.

(3-5 gears)

Last Gear: The program lets you select the number of gears to use with the shift light from

2-6 gears. Default is five gears.

ALERTS

This is only used with the Hand Held Monitor, PN 7550. You can program an alert to interrupt the

screen on the monitor. You can select which alerts to show and how often. The alerts are No Cam

Sync, Low Battery, and Traction Control Detection (TCD).

Fault: Program the number of counts that occur for a Low Voltage alert.

BrownOut 0: This is the count of low voltage resets. This should always be set at 0.

WatchDog: The count of Watch Dog resets. This should always be set at 0.

TCD: When a traction control device is detected an alert is set and will flash a Code 4 (a 4

blink sequence) on the end panel LED. This alert will continue to flash until the ignition is kept

turned On for 24 hours in order to reset.