MSD 7530T Programmable Digital-7 Ignition Control Installation User Manual

Page 6

Advertising
background image

6

INSTALLATION INSTRUCTIONS

M S D  

•   W W W . M S D P E R F O R M A N C E . C O M   •   ( 9 1 5 )   8 5 7 - 5 2 0 0   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

REV LIMITS

Up to three different rev limits can be programmed in 100 rpm increments.

RevBurn: Burnout Rev Limit. This limit is activated when 12 volts are applied to the Light Blue

wire. It is adjustable from 2,000 to 12,500 rpm.

RevLaunch: Launch Rev Limit. This limit is activated when 12 volts are applied to the Dark

Blue wire. It is adjustable from 2,000 to 12,500 rpm. This Limit has priority over all the other

rev limits.

RevMax: Max Speed Rev Limit. This is the overrev limit and is active whenever the Launch

and Holeshot limits are off.

OutCam: Select either a Cam Sync output or a Rev Limiting output that can be used with

MSD components that use rpm modules for the rev limit.

AdjOff: This program enables an automatic compensating rev limiter that will correct trigger

input offsets and variables. It can be turned On or Off.

RPM: Adjustable in 100 rpm increments from 2,000 – 12,500.

TIMED SAFETY REV LIMIT

This provides a time activated rpm limit ramp that is designed to work as a safe shutdown. The ramp

will lower the rpm to an adjustable amount, within two seconds after it is activated. The activation point

ranges from 1-12.5 seconds after the burnout and the shutdown rpm value can be set from 1000-

12,500 rpm. The time before the safety RPM Limit ramp is activated begins when the Dark Blue wire

is released from 12 volts,

and only if the programmed Launch Rev Limit rpm has been acheived

on the starting line.

START RETARD

Program an amount of retard that will occur while the engine is cranking. This helps reduce the load

on the starter for easier cranking. It is adjustable from 0° - 25° in 1° increments. This is an automatic

feature and will enable below 500 rpm and will deactivate when the engine reaches above 800 rpm.

Default is 10°.

LAUNCH RETARD

This is the time based retard ramp. It can be programmed from 0°-15° in 0.1° increments and from

0-2.5 seconds. When the Dark Blue Launch/Reset wire is connected to 12 volts, the retard value is

activated and is added to the retard sum. When 12 volts are removed from the Dark Blue wire, the

retard value begins to ramp up to 0° over the programmed time. Once the time is over, the retard will

not be activated again.

TCD

The PN 7530T Ignition incorporates a unique Traction Control Detection (TCD) circuit. This software

code monitors the magnetic pickup circuit for changes that would only come from an installed traction

control device that would modify the signal from the mag pickup. If a modification is sensed in this

circuit an Alert will be set and the status LED will flash a Code 4. This Alert will continue to flash until

the ignition is kept turned On for 24 hours in order to reset. A 4000 rpm TCD Rev Limit is activated

until the 24 hour TCD timer is elapsed or reset by an NHRA official.

Advertising