Configure the settings relating to the alarm output terminal

Select the alarm output operation. Follow the procedure below.

Step 1

Move the cursor to "ALARM IN/OUT" and press the setting button.

→ The "ALARM IN/OUT" screen appears.

Step 2

Move the cursor to "ALARM OUT" and select the alarm output terminal operation from the following.
OFF (default): Does not perform terminal output.
ALARM: The alarm output will be performed upon a i-VMD detection. The alarm output will also be performed when receiving

an alarm input while operation with setting "ALARM" for "ALARM IN".

BW: Activates the output terminal while an image is displayed in the black and white mode.

12. Privacy zone setting [PRIVACY ZONE]

When undesired portions in the camera shooting area (on the screen) exist, those portions (privacy zone) are hidden. Up to 8
portions can be specified for the privacy zone.
ON (1): Grays the zone.
ON (2): Mosaics the zone.
OFF (default): Displays the zone normally.
Follow the procedure below.

Note:

• The privacy zone function is disabled at initializing the unit, i.e. right after turning on the power.

Step 1

Move the cursor to "PRIVACY ZONE", select "ON (1)" or "ON (2)", and press the setting button.

→ The zone setting screen appears.

**SYSTEM SETUP**

SYNC INT

ALARM IN/OUT

PRIVACY ZONE OFF

STABILIZER OFF

EL-ZOOM OFF

RET TOP END

"ALARM IN/OUT" screen

"SYSTEM SETUP" screen

**ALARM IN/OUT**
ALARM IN OFF

ALARM OUT OFF

RET TOP END

**SYSTEM SETUP**

SYNC INT

ALARM IN/OUT

PRIVACY ZONE ON(1)

STABILIZER OFF

EL-ZOOM OFF

RET TOP END

"SYSTEM SETUP" screen

Zone setting screen

**ZONE NUMBER 1 /8**
POSITION PUSH SW
UPPER LEFT

DEL

RET TOP END