THE MILTON NO. 825 REMOTE CONTROL AIR SWITCH IS AN AIR OPERAT E D
MOMENTARY CONTACT ELECTRICAL CONTROLLER. IT WILL OPERATE ALL MILTON
REMOTE CONTROLLED SIGNALS (MODELS 827 AND 830) AS WELL AS BELLS,
BUZZERS, LIGHTS, ETC. IT WILL ALSO OPERATE RELAYS FOR INDUSTRIAL
APPLICATIONS.

ELECTRICAL RATING
0 - 240 VOLTS AC OR DC, 10 AMPS

STANDARD HOOK-UPS

FOR

MODEL 825

OPTIONAL

STANDARD

DOORBELL OR BUZZER

SECONDARY
10 VOLTS AC

OPTIONAL

830

CHIME

825

PRIMARY

110 - 125 VOLTS AC

827

BELL

8

27

BELL

MOMENTARY
AIR SWITCH

10

AMPS MAX.

REMOVE SMALL

COVER

NOT USED

SIGNAL AIR HOSE.

PLACE ACROSS

DRIVEWAY. PLUG

UNUSED END.

110 - 125 VOLTS AC

(OR 6 - 220 VOLTS AC OR DC WITH

MATCHING VOLTAGE UNITS)

This is a pictorial wiring diagram to suggest various hook-up options and to show a
typical circuit path. Any installation must be properly terminated and insulated and must
conform to all applicable codes. Consult a qualified electrician.
NOTE: The center terminal on the terminal strip can be used as a convenient tie point if
desired.

IMPORTANT:

The model 825 must always be mounted with the hose connector tube

pointing straight down. Remove plastic cap before attaching hose.

STANDARD HOOK-UPS

FOR

RELAY APPLICATIONS

LATCHING RELAY CONNECTOR

(OPTIONAL)

RESET

(OR UNLATCH)

SWITCH N.C.

TO CIRCUIT TO

BE CONTROLLED

RELAY

USER SUPPLIED

MUST MATCH

POWER SOURCE

TO RELAY

POWER SOURCE

0 - 240 VOLTS AC OR DC

SIGNAL AIR HOSE.

PLUG UNUSED END.

10

AMPS MAX.

MOMENTARY
AIR SWITCH

(NORMALLY OPEN)

(NORMALLY OPEN)

STANDARD BELL

TRANSFORMER

825

UP TO 10 ADDITIONAL

UNITS (OPTIONAL)

Advertising