Set-up auto settings – Snap-On 5000-3 User Manual

Page 29

Advertising
background image

SETUP AND PROGRAMMING

CHAPTER 3

3. Press Enter (

↵). The display reads:


4. Press --> (F5) or <-- (F6) to select High or Low limit.



5. Use Left (

←) or Right (→) Cursor to select a digit to be changed.

6. Increment or decrement the selected digit by pushing Up (

↑) or Down (↓) cursor.

Push and hold Up (

↑) or Down (↓) Cursor to change the display quickly.

7. Select and change the next digit using Left (

←) and Right (→) DIGIT and Up (↑) or

Down
(

↓) cursor, respectively. Continue until all digits are set.


8. Press (Save) to save and to return to measurements mode.


Set-up AUTO Settings

Use AUTO Settings to program the CLEAR, STORE and SEND functions for
automatic or manual operation. Use these functions in PEAK HOLD, POWER TOOL
and FIRST PEAK modes to STORE torque measurements to memory, CLEAR the
display, and SEND the last measurement captured on the display to the printer or PC.
Auto STORE and SEND are initiated at either auto or delayed CLEAR operations.

Use the manual modes to:

• Store the present reading by pushing STORE, (F5) in all measurements modes.
• Clear a captured display by pushing CLEAR, (F6) in measurements modes.
• Send a measurement to the printer/port by pushing SEND, (F4) in measurements
modes.

Use the automatic modes to:

• Store the last measurement, and/or
• Send the last measurement to the printer/port by initiating the auto or delayed function.

Auto CLEAR can be programmed with a 1 to 9 second delay. Use this feature to visually
note the reading before the display clears. Auto CLEAR with no delay stores, prints
and/or clears with no delay at the initiation of the next torque input

STORE (F5) must be pressed manually to save the last reading. Auto CLEAR must be
selected to use auto
STORE and auto SEND.

3-6