Peerless Lighting CLW9 - T5_T5HO User Manual

Contrail wall, Indirect-direct t5/t5ho, Wall mount

Advertising
background image

LAMPING OPTIONS

SPECIFICATIONS

CATALOG NUMBER

S P E C I F I C A T I O N S

2246 5th Street, Berkeley, CA 94710

Tel: 510.845.2760

Fax: 510.845.2776

Email: [email protected]

PeerlessLighting.com

__________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ __________ _____________________

R2

R3

R4

R8

1

/

4

1

/

4

1

/

4

1

/

4

1

/

4

1

/

4

4’

4’

1

1

/

4

1

/

4

1

/

4

2’

3’

4’

Type:

________________________

Project:

______________________


1

© 2012 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” and “Contrail” are registered trademarks of Acuity Brands Lighting.

Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.

1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/customerresources/terms_and_conditions.aspx

Indirect-Direct T5/T5HO

CLW9  Contrail Wall

3 Option EL or EN (Battery Pack) is not permitted in 2’, 3’, 4’ section.

4 ALC (Alternate Lamping Module Circuit) is not available with dimming.

Notes:

1 Not available in 347V

2 Not available with 28T5 lamps

Construction

Cold rolled steel housing. Die-cast aluminum

end caps.

Shielding

GrateOptic curved, crenulated diffuser is extruded

opal acrylic. Shielding can be rotated to one of two

positions, wall-facing or ceiling-facing.

Reflectors

Die-formed, white, high reflectance aluminum

reflector.

Finish

Housing cover is painted white. Select white or

painted aluminum finish for joiners and end caps.

Electrical

Specify 120V, 277V or 347V. Pre-wired with 16AWG

fixture wires. For special circuiting or wire gauge,

consult factory. Plug-in electrical connectors

included. UL and C-UL listed.

Luminaire Length

Individual luminaire lengths in a single section are

2’, 3’, 4’ and 8’. For total luminaire length, add

1

4

for each end cap. Using internal joiners, 2’, 3’, 4’

and 8’ sections can be joined to form longer length

luminaires. Lenses are not continuous in a run or

8’ unit. Lenses are separated by a 1

1

4

” gap between

lamp modules.

Examples:

CLW9 1 28T5 40FT R8 277 GEB10 SCT LP835 C041 — CLW9 1 54T5HO 32FT R8 277 GEB10 1SE EL SCT LP835 C110

Wall Mount

CLW9

Contrail Wall

Indirect-Direct T5/T5HO

5”

5

3

8

3”

CLW9

__________

__________

__________

_________

__________

__________ __________

__________

__________

Luminaire

CLW9

# of Lamps in

Cross Section

1

Lamp Type

28T5 28W T5

54T5HO 54W T5HO
Available for 3 FT:

21T5 21W T5

39T5HO 39W T5HO

Available for 2 FT:

14T5 14W T5

24T5HO 24W T5HO

Luminaire Row

Length

2 FT

3 FT

4 FT

8 FT

X FT

Maximum

Section

Length

R2

2’ section(s)

R3

3’ section(s)

R4

4’ section(s)

R8

8’ section(s)

Voltage

120

277

347

2

Ballast Type

GEB10

<10% THD Electronic

ADEZ

1,2

Advance Mark 10 dim

DMHL3D

1

Lutron Hi-Lume dim

OSDIM

1,2

Osram 0-10V dim

Reference

Ballast Wizard

on website

or consult factory for other options.

# of Emergency

Modules

(Blank) None

1SE

1 section

2SE

2 sections

XSE

X sections

Emergency Type

3

(Blank) None

EC

Emergency circuit

EL

Emergency battery pack

EN

Emergency battery pack

w/night light circuit

______________

________________

______________

_________________________________

Switching

SCT

Single circuit

ALC

4

Alternate Lamping

Module Circuit

Lamp Color

L/LP No lamp

LP830 3000k 80+ CRI

LP835 3500k 80+ CRI

LP841 4100k 80+ CRI

Available with T5 only:

LP830P 3000K 80+ CRI Premier

LP835P 3500K 80+ CRI Premier

LP841P 4100K 80+ CRI Premier
Reference

Lamp Chart

on website or

consult factory for other options.

Joiner/End Cap Finish

C041 White white (low gloss)

C110 Painted aluminum (low gloss)

Options

DL

Damp location label

DU

Dust cover

ELH

Emergency through wiring w/separate feed

ELS

Emergency through wiring w/single feed, shared neutral

ELS2 Emergency through wiring w/single feed, separate neutrals

GLR Fusing (fast blow)

GMF Fusing (slow blow)

Advertising