PPT30ME Series
30 Watt Switch Mode
Universal AC Input

INPUT
Input Voltage Range

90 - 264Vac

Frequency

47 - 63Hz

Input Current

0.4 - 0.8A max.

Inrush Current

50A max. @ 240Vac

Conducted EMI

CISPR/FCC Class B

Isolation - Input/Output

5,656VDC

Leakage Current

100µA max.

OUTPUT
Hold-up Time

10mS typ. @ 115Vac

Short Circuit Protection

Continuous (Auto Recovery)

Over Voltage Protection

Yes

ENVIRONMENTAL
Operating Temperature Range

0°C to +40°C

Storage Temperature Range

-20°C to +85°C

Cooling

Natural convection

GENERAL
Safety Approvals

cUL/UL 60950, TUV EN60950, cUL/UL2601-1, TUV EN60601-1

Dimensions

108.67 x 61.98 x 36.70 mm
4.270 x 2.440 x 1.445 inches

Weight

300g

Electrical Specification

The PPT30ME series of CEC level IV compliant AC-DC
Power Adaptors offer user interchangeable AC input
plugs to enable operation in many different countries.
Adaptors can be ordered with up to 4 different
interchangeable plugs to meet the power socket
requirements of most countries.

Features

Universal Input Range 90-264VAC

Over Voltage & Continuous Short Circuit Protection

Meets EN60601-1 & EN55011 Class B

CEC Level IV Compliant (Output Cable Length ≤1800mm)

(PPT30ME-050: Output Cable Length ≤1500mm)

Optional Output Connector

www.powersolve.co.uk

Output Voltage and Current Ratings

MODEL

OUTPUT

OUTPUT CURRENT

RIPPLE &

VOLTAGE

LINE

LOAD

% EFF.

VOLTAGE

Min.

Max.

NOISE

ACCURACY

REG.

REG.

PPT30ME-050

5V

0A

4.0A

1%

±2%

±1%

±6%

73%

PPT30ME-090

9V

0A

3.0A

1%

±2%

±1%

±3%

76%

PPT30ME-120

12V

0A

2.5A

1%

±2%

±1%

±2%

79%

PPT30ME-150

15V

0A

2.0A

1%

±2%

±1%

±2%

81%

PPT30ME-180

18V

0A

1.67A

1%

±2%

±1%

±2%

81%

PPT30ME-240

24V

0A

1.25A

1%

±2%

±1%

±2%

83%

NOTE:
1. Voltage set point at 60% full load.
2. Output noise and ripple measured with 10µF electrolytic & 0.1µF ceramic capacitors across output at 20MHz BW.
3. Line regulation is measured from 100Vac to 240Vac at full load.
3. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% load).
Typical at 25°C, nominal line and 75% load unless otherwise stated.