S2240600003F3F3F3C20000004200000072000000720000007200000072000000720000007CE

The databytes to be programmed. These bytes form the top eight pixelrows
of the icon.

S2240600003F3F3F3C20000004200000072000000720000007200000072000000720000007CE

The Checksum

How to download S-Records to the Discovery.

Note : Only one sector at a time can be written to. This means that font sets can

not be downloaded together with images and Icons.

The Discovery uses S-Records for downloading flash information. Once you have

created an S-Record file, containing your images or fonts, you probably would

like to upload these to a Discovery.

This can be achieved following these steps :

A

Initiating the download sequence.

B

Sending the S-Records

A

Initiating the download sequence.

The Discovery first has to clear the target area inside the flash memory, before

anything can be written to it.

*

Send the following command to the Discovery:

0x08<Start Address><Length>

0x08

The command

Start Address

The start address of the area which is to be cleared.

Field length : 5 bytes.

Use ASCII characters to form the address in hex notation.

eg : 0x52A00 should be formed as ASCII characters

'5' '2' 'A' '0' '0'

(or in hex values : 0x35 0x32 0x41 0x30 0x30)

Length

The length of the area to be cleared

Field length : 4 bytes

Use ASCII characters to form the length in hex notation.