7. Own Port: The Port number to communicate on

8. Remote IP Address: the IP Address the Discovery is sending its data to, in

case the unit is configured as Client or UDP.

9. Remote Port: The remote port

10. Subnet Mask: Enter The Subnet mask

11. Gateway: The gateway to communicate through. Enter 0.0.0.0 if not used

12. Connect Mode, there are 3 options:

-

TCP Client: The Discovery tries to connect to the remote IP Address +

Port, using TCP

-

TCP Server: The Discovery waits for a client to connect, using TCP

-

UDP: uses the connectionless datagram protocol

13. Other settings: The Ethernet module has many more settings than the ones

above. This option determines what to do with those, when saving the

above settings

Leave unmodified: When saving the above settings, all other settings are

left unmodified. To be used if customer-specific Ethernet settings are used.

Discovery defaults: When saving the above settings, all other settings are

returned to Scantech factory defaults.