Installation, Positioning – Hotpoint Ariston TD 640 S (ICE) IX-HA User Manual

Page 13

Advertising
background image

GB

13

 Before operating your new appliance please read this

instruction booklet carefully. It contains important information

for safe use, installation and care of the appliance.
 Please keep these operating instructions for future

reference. Pass them on to possible new owners of the

appliance.

Positioning

 Keep packaging material out of the reach of children. It

can become a choking or suffocation hazard (see

Precautions and tips).
 The appliance must be installed by a qualified professional

according to the instructions provided. Incorrect installation

may cause harm to people and animals or may damage

property.
 This unit may be installed and used only in permanently

ventilated rooms in accordance with British Standard Codes

Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891

Current Editions. The following requirements must be

observed:
• The room must be equipped with an air extraction system

that expels any combustion fumes. This may consist of a

hood or an electric fan that automatically starts each time

the appliance is switched on.

• The room must also allow proper air circulation, as air is

needed for combustion to occur normally. The flow of air

must not be less than 2 m

3

/h per kW of installed power.

The air circulation system may

take air directly from the outside

by means of a pipe with an inner

cross section of at least 100 cm

2

;

the opening must not be

vulnerable to any type of

blockages.

The system can also provide the

air needed for combustion

indirectly, i.e. from adjacent rooms

fitted with air circulation tubes as

described above. However, these

rooms must not be communal

rooms, bedrooms or rooms that

may present a fire hazard.

• Liquid petroleum gas sinks to the floor as it is heavier

than air. Therefore, rooms containing LPG cylinders must

also be equipped with vents to allow gas to escape in

the event of a leak. As a result LPG cylinders, whether

partially or completely full, must not be installed or

stored in rooms or storage areas that are below ground

level (cellars, etc.). It is advisable to keep only the

cylinder being used in the room, positioned so that it is

not subject to heat produced by external sources

(ovens, fireplaces, stoves, etc. ) which could raise the

temperature of the cylinder above 50°C.

Fitting the appliance
Gas and mixed hobs are manufactured with type X

degree protection against overheating. The following

precautions must be taken when installing the hob:
• Kitchen cabinets adjacent to the appliance and taller

than the top of the hob must be at least 600 mm from

the edge of the hob.

• Hoods must be installed according to their relative

installation instruction manuals and at a minimum

distance of 650 mm from the hob.

• Place the wall cabinets adjacent to the hood at a

minimum height of 420 mm from the hob (see figure).

If the hob is installed beneath a

wall cabinet, the latter must be

situated at a minimum of 700 mm

above the hob (see figure).

• The installation cavity should have the dimensions

indicated in the figure. Fastening hooks are provided,

allowing you to fasten the hob to tops that are between

20 and 40 mm thick. To ensure the hob is securely

fastened to the top, we recommend you use all the

hooks provided.

555

mm

475

m

m

55

mm

• Before fastening the cooktop in place, position the seal

(supplied) along the perimeter of the countertop, as

shown in the figure.

Installation

Enlarging the ventilation slot
between window and floor.

Adjacent
Room

Room to be
Vented

A

Examples of ventilation holes
for comburant air.

In a chimney stack or branched flue.
(exclusively for cooking appliances)

Directly to
the Outside

600mm min.

540mm min.

700mm min.

Advertising
This manual is related to the following products: