RH 

RC 

Program Thermostat Owners Manual 

Model  CP1820 

We are pleased you have selected one of our broad line of wall thermostat. Our products 

are manufactured to high quality standards and are designed for years of service. 

Read This Before Installing Thermostat 

OPERATION 

1,Your Thermostat is designed to operate with most gas , oil, electric or 2­wire hot water 

heating, and air conditioning systems that have 24­volt or millivolt control. 

This  Thermostat  will  not  control  multistage  heating  or  cooling  systems,  110  /  220V 

systems, or 3 wire zone systems. 

IMPORTANT 

2,Read  the  entire  installation  of  this  Owner’s  Manual  thoroughly before  you  begin  to 

install or operate your Thermostat. 

Remove the mylar label from the display window. 

INSTALLATION 

3,All installation is normally performed at your thermostat. 

PROGRAMMING 

4,You  can  practice  programming  before  installing  your  thermostat  by  inserting  and 

connecting the batteries. This can be done while you relax in your favorite chair and is a 

very good way to familiarize yourself with all the functions of your Thermostat. 

COMPRESSOR PROTECTION 

5,The thermostat provides a 4­minute delay after shutting off the compressor before it 

can  be  restarted. This  feature  will  prevent  damage  to your  air  conditioner  compressor 

caused by rapid cycling. It does not provide a delay when there are power outages. 

TEMPERATURE RANGE 

6,  This  thermostat  can  be  programmed  between  45˚F  and  95˚F  (7˚C  and  35˚C). 

However, it will display room temperatures from 30˚F to 99˚F (0˚C and 37˚C). “HI” will be 

displayed if the temperature is higher than 99˚F (37˚C), and “LO” will be displayed if the 

temperature is lower than 30˚F (0˚C). 

This  thermostat  will  automatically  cutoff  in  Heat  mode  if  the  temperature  rises  above 

95˚F (35˚C), and automatically cutoff in Cool mode if the temperature drops below 45˚F 

(7˚C). 

POWER FAILURE 

7,  Whenever  the  main  power  is  interrupted  or  fails,  the  battery  power  retains  the 

programs and current time. 

BATTERY WARNING 

8,Two  fresh  AA  alkaline  batteries  should  provide  well  about  one  year  of  service. 

However, when the batteries become drained, the “BATT” will flash on the display. When 

this message occurs, install new alkaline batteries. You have approximately 1 minute to 

change  the  batteries  and keep  the thermostat’s clock  and  program  settings.  Once the 

batteries have become too low to ensure proper operation, your system will be turned off, 

and the display will be cleared except for flashing “BATT” on the lcd display. 

CAUTION: When only the Low Battery icon flashes on the display, the 

thermostat is shut down, and your system will no longer operate. In this 

condition, there is no temperature control of your dwelling. 

NOTE: The backlight will not function when the thermostat is in low battery condition. 

NOTE: If you plan to be away from the premises over 30 days, we recommend that you replace 

the old batteries with new alkaline batteries prior to leaving. 

POWER SUPPLY 

9,The thermostat shall be powered by 24 VAC and with batteries as backup. 

How This Thermostat Works …And Saves Your Money 

This thermostat is designed to optimize the use of your heating and cooling equipment. It 

does this by matching your comfort (the temperatures in your home) to your schedule. 

An example: 

6:00am  – You wake up. Program 1 has the heat set to 70°(21℃). 

7:30am  –  You  leave  for  work.  The  second  program  turns  the  heat  back  to 

62℃(17℃) while you are away. 

5:00pm – You come home. The third program has already warmed your house 

back to 70°(21℃) . 

10:00pm  –  You  go  to  bed.  A  half  hour  later,  program  4  turns the  heat  back  to 

64°(18℃) to save energy while you are under the blankets. 

FEATURES 

Installation 

What You Need 

This thermostat comes with two #8 slotted screws and two wall anchors for mounting. To 
install your unit, you should have the following tools and materials. 

■ Slotted screwdriver        ■ Electric drill and 3/16” bit 

■ Hammer 

■ Two 1.5V(AA) Size Alkaline batteries are included. 

Remove Old Thermostat 

CAUTION: Do not remove any wiring from existing thermostat before reading the 

instructions carefully. Wires must be labeled prior to removal. 

■ 

IMPORTANT! Turn off the power to the furnace at the main power panel or at the 

furnace. 

■ 

Remove existing thermostat cover and thermostat .See figure 1.Some thermostat 

will  have  screw  or  other  locking  devices  that  must  first  be  removed.  Once  wall 

mounting plate is exposed, look for wires. 

If wires are not visible, they may be connected to the back of the wallplate. Again, 

look for screws, tabs, etc. Some models have doors that open to expose wires and 

mounting screws. (See Figure 1). 

TYPICAL HOME THERMOSTAT 

FIGURE 1 

Wall Mounting Plate          Thermostat                Cover 

Wall Mounting Plate          Thermostat                Cover 

Label Wires 

■ 

Each  wire  coming  from  the  wall  to  the  existing  thermostat  is  connected  to  a 

terminal point on that thermostat. Each of these terminal points is usually marked 

with a code letter as shown in Table A. 

The number of wires in your system can be as few as two (for heat only systems), 

as many as eight, or any number in between. If you follow the labeling procedures 

correctly, you do not have to concerned about how many wires there are. 

There  is  often  no  terminal  marking  on  the  existing  thermostat  of  two  wire,  heat 

only systems. Don not worry, just connect either of the wires to the RH terminal, 

then connect the other wire to the W terminal to complete the circuit. 

■ 

IMPORTANT!  BEFORE  DISCONNECTING  ANY  WIRES,  APPLY  THE 

SELF­ADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN TABLE A. 

(For  example,  attach the  label  marked W to the  wire  which  goes to the W or  H 

terminal  on  your  existing  thermostat.)  IGNORE  THE  COLOR  OF  THE  WIRES 

since these do not always comply with the standard. 

■ 

After labeling wires, disconnect them from the existing thermostat terminals. 

■ 

Remove existing wallplate. To make sure wires do not fall back 

into wall opening, you may want to tape them to the wall. 

■ 

If hole in wall is larger than necessary for wires, seal this hole 

so that no hot or cold air can enter the back of the thermostat 

form the wall. This air could cause a false thermostat reading. 

Wire Labeling 

This table will help 

you match the labels 
to the wires so you 

can attach them to 
your thermostat. 

NOTE: Follow the 

labels when 
connecting wires 

since many 
installations do not 

follow color 
coding of wires. 

Wire Labeling 

NOTE: If your thermostat has one wire marked R or RH (4­wire system), then 

leave the jumper wire between the RH and RC terminals. Otherwise, if you 

have  separate  RH  and  RC  wires  (5­wire  system),  then  remove  the  jumper 

wire between the RH and RC terminals. 

NOTE:  Do  not  connect  a  “common”  wire  (sometimes  labeled  “C”)  to  any 

terminal  on  this  thermostat.  Tape  up  the  wire  and  do  not  use.  This  wire 

provides electricity      to non­battery powered thermostats. 

Mount Wallplate and Thermostat 

Snap open the wallplate your thermostat by pressing the release tab on the bottom of the 

thermostat. 

Position  wallplate  on  wall  and  pull  existing  wires  through  large  opening.  Then 

level for appearance. Mark holes for plastic anchors provided if existing holes do 

not line up with Hunter Thermostat holes. 

Drill holes with 3/16” bit and gently tap anchors into the holes until flush with wall. 

Reposition wallplate to wall, pulling wires through large opening. Insert mounting 

screws provided into wall anchor and tighten. (See Figure 2.) 

Figure 2 

Selector witches 

The  heating system  selector  and the ℉/℃ selector  switches  are  located  on  the 

Printed Circuit Board. 

 

Heating system selector 

The heating system selector is a switch on the Printed Circuit Board on the inside 

of  the  thermostat.  The  switch  is  at  “HG”  position.  Leave  it  in  this  position  if you 

have a gas furnace or an oil burner. 

If you have an electric furnace, test to see whether the heat and fan come on as 

expected. Leave the switch in the “HG” position. If the fan does not come on when 

the thermostat calls for heat, change the switch position to “HE”. 

The system selector has no effect in the cooling mode. 

NOTE: “HG” position is for gas and most other systems. “HE” position is for 

certain electric systems having a fan relay. 

■ 

/ selector (Fahrenheit/Centigrade) 

Your  thermostat  is  set  for ℉  mode  from  the  factory.  In  order  to  change  to ℃ 

mode, slide the switch to ℃ and move 

the battery out, and then hold any key 

to release the rest energy.  Then place 

the battery again. 

NOTE:  Unless  move  the  battery  out, 

and  then  hold  any  key  to  release  the 

rest  energy.  Then  place  the  battery 

again,the  thermostat  will  not  change 

the mode. 

Auto Recovery select 

Your thermostat is set from the factory with the Auto Recovery Feature enabled , 

which complies with the EPA ENERGY STAR Program. If you prefer to use normal 

recovery, slide the switch to the ENABLE position. 

Connect Wires and Mount Thermostat Cover to Wall Plate 

■ 

Match and connect the labeled wires to the appropriate coded terminal screws on 

the mounting plate.(See Figure 3, 4.) Ignore any wires which may be present, but 

which were not connected to the old thermostat. 

■ 

Be  sure  to  tighten  the  terminal  screws  securely,  otherwise  a  loose  wire  could 

cause operational problems with your system or thermostat. 

■ 

Push excess wire back into hole to prevent interference with mounting of the thermostat cover. 

■ 

Make sure the Function Switch is set at OFF, and the FAN­AUTO Switch is in AUTO. 

■ 

Insert  the  bottom  tab  on  the  thermostat  body  into  the  slot  at  the  bottom  of  the 

wallplate. Press top of the thermostat body to snap it into the wallplate. 

 

(NOTE: Do not force the thermostat onto the wallplate, as the terminal pins 

may be damaged. If it does not snap properly, the thermostat may not work.) 

■ 

Insert the two AA size batteries, observing the 

polarity marked on the unit. 

■ 

The installation is now complete. Continue reading 

Figure 3 

Figure 4, 

Programming 

1 Remove mylar label covering display window. 

2 When the heating or cooling systemis actually operating, ”HEAT” or “COOL” will appear on this display. 

3 If power is interrupted the batteries will keep all programs. 

4 If “BATT” indicator appears on the display replace the batteries. 

Setting the Time and Day of Week 

When you first install the two AA batteries, the thermostat automatically sets the day and 

time to Monday, 12:00 a.m., The first data you should enter is the current time and day of 

work. As the keys are pressed, the display will show the data being entered. 

EXAMPLE: If the unit is being Installed at 9:15 p.m. Saturday, to set the thermostat, you 

would press the keys in the shown sequence. 

■ initial read­out 

■Current room temperature is 72°. 

■ Press once. Temperature digits 
disappear, show time set mode. 

■ Press and hold until current hour 

appears on display. 

■ Note the AM/PM indicator. 

■ Press and hold until current hour 

appears on display. 

■ Press until current day appears on display. 

■ Returns to normal time and temperature. 

■ If run Key is not pressed it will return 

automatically in 10 seconds. Figure 4, 

Typical Suggested Summer and Winter Programs for Maximum Savings 

Studies conducted by the Department of    Energy estimate that setting your thermostat back 10℉ 

for two 8­hour periods during winter can reduce your fuel bill by as much as 33%. By setting your 

thermostat up 5°for two 8­hour periods during summer you  can reduce your fuel bill up to 25%. 

Your thermostat is capable of holding up to 4 separate programs for each day of the week. You 

can program all weekdays, Monday to Friday, to the same 4 programs as shown in the table, or 

each weekday can have a different set of 4 programs. Similarly weekend programs, Saturday and 

Sunday,  can  be  the  same  4  programs  or  each  weekend  day  can  have  a  different  set  of  4 

programs. 

A typical set of programs is shown in Table 3. 

The following time and temperature settings are pre­programmed into the thermostat: 

MO TO FR 

Temperature in F˚ (C˚) 

Program 

Number 

Time 

Heat 

Cool 

6:00 am 

68˚F(20˚C) 

78˚F(26˚C) 

8:00 am 

60˚F(16˚C) 

85˚F(29˚C) 

4:00 pm 

68˚F(20˚C) 

78˚F(25˚C) 

10:00 pm 

62˚F(16˚C) 

82˚F(27˚C) 

SA AND 

SUN 

Temperature in F˚ (C˚) 

Program 

Number 

Time 

Heat 

Cool 

6:00 am 

68˚F(20˚C) 

78˚F(25˚C) 

8:00 am 

62˚F(16˚C) 

82˚F(27˚C) 

4:00 pm 

68˚F(20˚C) 

78˚F(25˚C) 

10:00 pm 

62˚F(16˚C) 

82˚F(27˚C) 

When  your  program  becomes  effective  at  the  next  time/temperature  setting,  the 

appropriate corresponding program number will appear on the display. 

Personal Program Schedule 

Before programming or changing the 

Use a pencil so you can revise your records 

program, use this Personal Program Schedule      each time you change your    temperature 

to determine which times and temperature 

settings. 

settings will best satisfy both your comfort 

and energy saving requirements. 

heat 

off 

cool 

on 

auto 

system 

fan 

LCD Display:Shows 
Time,Day,Temperature, 
Program Number,and 
other feature information 
as required. 

Backlight button for 

Battery Compartment: 
Front access allows 
easy insertion of two 
AA 1.5V batteries. 

Up and Down Key:Key for 
changing the Temperature 
setting. Also used for increasing 
and decreasing selections in the 
Time,Program,and Span 
functions. 

Fan Switch: Fan 
switch for Automatic 
or Continuous fan 
operation. 

System Switch: 
Selector switch for 
Heat,Cool,and Off. 

Front Door:Covers keys Open with one finger from left or right. 

Soft touch programming 
buttons (see below) 

viewing in the dark. 

Front Door: 

Battery cover 
Open with one 
finger from top. 

FILTER 

HOUR 

MIN 

DAY 

PROG 

AUTO 

DAY 

HOLD 

RUN 

CLEAR 

PROG 

PROG 

12/24 

HOURS 

For entering 
hour of day. 

For entering 
minute of day. 

For entering 
day of week. 

Automatically programs 
thermostat for weekday 
and weekend program 
settings. 

For reviewing 
and changing 
weekday or 
weekend 
programs 

Picks the day/days 
for programs 

Provides permanent temperature 
setting by overriding stored 
programs.Also,clears manual override 
and returns to current program. 

Reviews filter usage in hours and minutes. 
Also reset filter counter to zero. 

Returns display tocurrent 
time and temperature. 

12 hours/24 hours change. 

RH 

HOUR 

HOUR 

MIN 

DAY 

RUN 

heat 

off 

cool 

on 

aut o 

sys tem 

f an 

LCD Display:Shows 
Time,Day,Temperature, 
Program Number,and 
other feature information 
as required. 

Backlight button for 

Battery Compartment: 
Front access allows 
easy insertion of two 
AA 1.5V batteries. 

Up and Down Key:Key for 
changing the Temperature 
setting. Also used for increasing 
and decreasing selections in the 
Time,Program,and Span 
functions. 

Fan Switch: Fan 
switch for Automatic 
or Continuous fan 
operation. 

System Switch: 
Selector switch for 
Heat,Cool,and Off. 

Front Door:Covers keys Open with one finger from left or right. 

Soft touch programming 
buttons (see below) 

viewing in the dark. 

Front Door: 
Battery cover 
Open with one 
finger from top. 



RE COV ERY  E NA BLE 

DI SA BLE 

(HG­HE  SWI TCH) 

HG 

HE 

J P1 

K 2 

FAHRE NHE IT 

CE LSI US 

RH 

RC 

RH,R, 
VR or 4 
24 Volt 

RC,VC, 

24 Volt Cool 

G  or F 

Fan 

Y,C or M 
(See Note) 
Air Conditioning 

W or H 
Heating 

AC24V ­1 

AC24V ­2 

Rh 

Rc 

G

 

N

Advertising