C2G 26844 Tone Generator & Probe User Manual

Tone generator & probe, User manual, Introduction

Advertising
background image

Introduction

The Tone Generator is a highly practical network installation
and troubleshooting tool which features a single or multi-
tone signal, two test leads and a 4-conductor modular cable.
The signal emitted by the Tone Generator can be easily traced
by the Probe, even when cables are in a bundle or hidden in a
mess of punch down blocks or wall plates. The Tone
Generator & Probe can be used to verify cable continuity,
identify wiring faults, determine line polarity and voltage in
network (Cat 5 and Coax) and modular telephone lines. The
Probe is equipped with a tone amplifier and an LED indicator
that detects audible frequency tones for accurate tracing and
identification of wires.

Product Profile

Tone Generator

Features:
* 2-position switch for single tone or multi-tone signal
* Toggle switch to control 3 modes of operation
* 3-color LED indicator display for telephone line

BLACK TEST LEAD

RED TEST LEAD

TOGGLE SWITCH

4 PIN MODULAR CABLE

TONE SELECTING SWITCH

LED DISPLAY

BATTERY LOW

5

4

3

7

6

1

2

LOW BAT.

SIGNAL

PROBE

SPEAKER

DISPLAY MODE

VOLUME

TRACE

5

4

3

7

6

1

2

9V BAT.

8

Tone Generator & Probe

User Manual

E. Testing Continuity

1. Slide the toggle switch to the "Cont" position.
2. Connect the test leads to the subject pair.
3. A BRIGHT GREEN light indicates continuity.

Caution:

Do not connect to an active AC or DC circuit in this
mode.

F. Testing Continuity Using Tone

1. Slide the toggle switch to the "Tone" position.
2. Connect the test leads to the subject pair.
3. Using a handset or headset at the remote end,

touch the wire end(s) with the clip lead(s).

4. Reception of tone is an indication of continuity.

Modular Testing

* All above tests are applicable to modular plugs for line 1

only (red & green wires).

Coax Testing

* To test un-terminated coaxial cables, connect the RED

test lead to the outer shield and the BLACK test lead to
the center conductor, or connect the RED test lead to the
outer shield and the BLACK test lead to the ground.

* To test terminated coaxial cables, connect the RED test

lead to the connector housing and the BLACK test lead
to center pin, or connect the RED test lead to the
connector housing and the BLACK test lead to ground.

1

6

TONE GENERATOR

BAT.LOW

SINGLE TONE

DUAL TONE

GOOD

BAD

Cont

Off Tone

CABLE

TRACER

8

7

3

4

2

1

6

5

1

3

4

2

6

5

7