Alera Lighting L8 User Manual

Line 8, Technical installation data, Single mounting row mounting

Advertising
background image

Page 1/1 Rev. 01/14/14

RECESSED / L8 TID

LINE 8

Technical Installation Data

© 2014 Alera Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

7

1

8

" Max.

4¾" Min.

SINGLE MOUNTING

ROW MOUNTING

Flush Trim

Flush Flange Trim

Flange End View

Regressed Trim

Regressed Flange Trim

Grid Side View

Lay-in exposed grid. Fits standard 1" wide,
1½" tall tee.

Type F For hard ceiling applications. Yoke

hangers are shipped separately. Carrier
channel by others.

Type GF Fixtures mount on standard

exposed tees at end of fixture and support
tile at sides. Fits standard 1" wide, 1½"
tall tee.

9¼" I.D. Carr. Chan.

9¼" I.D. Carr. Chan.

Self aligning louver
tips into place

T8 shown above - results will vary with T5/T5HO lamps

C

B

A

A

A

A

C

C

B

A

A

A

A

C

A

A

Plaster Frame Opening:
8" × Nom. + ¼"

Housing Nominal Lengths:
2', 3', 4', 6', and 8'

Housing Nominal Lengths:
2', 3', 4', 6', and 8'

Knockouts:

A - ½" Mounting K.O.

B -

7

8

" Service K.O.

C - 2" × 3" Access K.O.

LOUVER RETENTION

For Yoke Mounting

3"

3"

Flange Opening: 8" × Nom. + ¼"

INSTALLATION DATA

6"

6"

6"

7¾"

8" R.O.

8" R.O.

8" R.O.

8" C-C Tees

8" C-C Tees

7¾"

7¾"

Nominal

INT (Intermediate Fixture) - Nominal

EOR (End of Row) - Nominal

Nominal

6"

5½" Max.

3" Min.

8

3

8

" O.A. Trim

8

7

8

" O.A. Trim

7¾"

Advertising