Specifications

Specifications

Table A-1 lists the specifications of the dc source. Unless otherwise noted, specifications are warranted
over the ambient temperature range of 0 to 55

°

C. Specifications apply with typical cellular phone

capacitive loads from 0

µ

F to 12,000

µ

F. Sensing is at the rear terminals of the power supply after a 30-

minute warm-up period. Sense terminals are externally jumpered to their respective output terminals.

Table A-1. Performance Specifications

Parameter

Agilent 66111A

Agilent 66311B/D;

Agilent 66309B/D

output 1 only

Agilent

66309B/D

output 2 only

Output Ratings

Voltage:

Current:

Peak Current:

0 – 15 V

0 – 3 A

5 A

1

0 – 12 V

0 – 1.5 A

2.5 A

2

Programming Accuracy
(@ 25

°

C

±

5

°

C)

Voltage:

+Current:

0.05% + 10 mV

0.05% + 1.33 mA

3

0.2% + 40 mV

0.2% + 4.5

mA

DC Measurement Accuracy
(via GPIB or front panel meters with
respect to actual output @ 25

°

C

±

5

°

C)

Voltage:

Current:

High Current range

4

+20 mA to + rated I:

20 mA to

rated I:

Low Current range

20 mA to +20 mA:

0.03% + 5 mV

see below

0.2% + 9 mA
0.2% + 9 mA

NA

0.03% + 5 mV

see below

0.2% + 0.5 mA

5

0.2% + 1.1 mA

0.1% + 2.5

µ

A

6

0.2% + 15 mV

0.2% + 3 mA

NA
NA

NA

Ripple and Noise
(in the range of 20 Hz to 20 MHz
with outputs ungrounded or with
either terminal grounded)

Voltage (rms/p-p):

Current (rms):

1 mV/6 mV

7

2 mA

1 mV/6 mV

7

2 mA

Load Regulation
(change in output voltage or current
for any load change within ratings)

Voltage:

Current:

2 mV

0.75 mA

1.6 mV

0.375 mA

Line Regulation
(change in output voltage or current
for any line change within ratings)

Voltage:

Current:

0.5 mV

0.75 mA

0.4 mV

0.25 mA

Transient Response Time
(for the output voltage to recover to
20 mV below its final setting)

< 35

µ

s

8

< 400

µ

s

9

1

Peak current for up to a 7 millisecond time period. Average current cannot exceed 3 A.

2

Peak current for up to a 1 millisecond time period. Average current cannot exceed 1.5 A.

3

0.05% +2.3mA when programming between zero and 0.03% of full scale current.

4

Agilent 66111A units do not have a low current range, the dc measurement accuracy applies from 0 amperes to the rated current.

5

Applies with current detector set to DC. ACDC mode accuracy is 0.2% + 3mA for sourcing and 0.2% + 3.6 mA for sinking.

6

This specification may degrade slightly when the unit is subjected to an RF field

3 V/meter.

7

Specification is for phone capacitance greater than 6

µ

F.

8

Applies to the negative portion of the output voltage transient waveform, following a 0.1 A to 1.5 A load current change.

(Applies with unit set to High capacitance compensation range with 5

µ

F

minimum output load capacitance.)

9

Following a 0.75 A to 1.5 A load change.