Atec HP-Agilent-66309D User Manual

Page 3

Advertising
background image

Specifications - A

145

Table A-2. Supplemental Characteristics (continued)

Parameter

Agilent 66111A

Agilent 66311B/D

Agilent 66309B/D

Measurement Time
(includes 30 ms

1

data

acquisition time and 20 ms
data processing overhead)

voltage or current

50 ms average

Command Processing Time
(time for output to begin to
change following receipt of
digital data)

4 ms average

Savable Instrument States
(applies only in SCPI mode)

4 (in locations 0 to 3)

GPIB Interface Capabilities

Language:

Interface:

SCPI or COMPatibility

2

AH1, C0, DC1, DT1, E1,

L4, PP0, RL1, SH1, SR1, T6

INH/FLT Characteristics

Maximum ratings:

FLT Terminals:

INH Terminals:

16.5 Vdc between terminals 1 and 2; 3 and 4; and

from terminals 1 or 2 to chassis ground

Low-level output current = 1.25 mA max.

Low-level output voltage = 0.5 V max.

Low-level input voltage = 0.8 V max.

High-level input voltage = 2 V min.

Low-level input current = 1 mA

Pulse width = 100

µ

s min.

Time delay = 4 ms typical

Digital I/O Characteristics

Maximum ratings:

Digital OUT Port 0,1,2

(open collector)

Digital IN Port 2:

(internal pull-up)

same as INH/FLT Characteristics

Output leakage @ 16V = 0.1 mA (ports 0,1)

= 12.5 mA (port 2)

Output leakage @ 5V = 0.1 mA (ports 0,1)

= 0.25 mA (port 2)

Low-level output sink current @ 0.5 V = 4 mA

Low-level output sink current @ 1 V = 50 mA

Low-level input current @ 0.4 V = 1.25 mA

High-level input current @ 5 V = 0.25 mA

Low-level input voltage = 0.8 V max.
High level input voltage = 2.0 V min.

Isolation to Ground
(Maximum from either output
terminal to chassis)

50 Vdc

Mains Input Ratings:
(at full load from 47–63 Hz)

100 Vac (87-106 Vac):

115 Vac (104-127 Vac):

220 Vac (191-233 Vac):
230 Vac (207-253 Vac):

1.7 A, 125 W
1.5 A, 125 W
0.8 A, 125 W

0.75A, 125 W

2 A, 170 W

1.7 A, 170 W

0.92 A, 170 W

0.85A, 170 W

1

May be reduced by changing the default conditions of 2048 data points but measurement uncertainty due to noise will increase.

2

Compatibility language is used to program the Agilent 663xA Series power supplies. Not all Agilent 66111A/66311B

capabilities are available when using the Compatibility language. Also, Compatibility language is not available for Agilent
66309B/D units.

Advertising