atwood LP GAS RANGE & SLIDE-IN COOKTOPS RV, CV, RA, CA (34) User Manual

Lp gas range & slide-in cooktops, Installation

Advertising
background image

1

SAFETY ALERT SYMBOLS

Safety Symbols alerting you to potential personal safety hazards.
Obey all safety messages following these symbols.

ƽ

WARNING

ƽ

CAUTION

avoid possible

avoid possible

injury or death

injury and/or property damage

FOR YOUR SAFETY

READ ALL INSTRUCTIONS BEFORE OPERATING APPLIANCE

Installer:

Provide these instructions to the consumer.

Consumer:

Keep documents for future reference.

ƽ

WARNING

FIRE OR EXPLOSION

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS

• Open windows.

DO NOT

touch any electrical switch, or use any phone or radio in

vehicle.

• Extinguish any open flame.
• Evacuate

ALL

persons from vehicle.

• Shut off gas supply at gas container or source.

DO NOT

start vehicle’s engine or electric generator.

• Contact nearest gas supplier or qualified Service Technician for

repairs.

• If you cannot reach a gas supplier or qualified Service Technician,

contact the nearest fire department.

DO NOT

turn on gas supply until gas leak(s) has been repaired.

FOR YOUR SAFETY

DO NOT

store or use gasoline or other flammable vapors and liquids

in the vicinity of this or any other appliance.

ƽ

WARNING

Improper installation, adjustment, service or maintenance can
cause injury, property damage or death. Refer to this manual. For
assistance or additional information, consult a qualified installer,
service agency, manufacturer or the gas supplier.

ƽ

WARNING

EXPLOSION OR FIRE

• Shut off all gas appliances and pilot lights when refueling gasoline

tanks, LP tanks or when vehicle is in motion.

• Atwood & Wedgewood gas operated cooking appliances are for

use with LP gas only, and for installation in recreation vehicles
only (e.g. travel trailers, motor homes, tent campers, etc.).

ƽ

WARNING

CARBON MONOXIDE POISONING

DO NOT

use cooking appliance for space heating. It is a potential

danger to occupants of vehicle and damage to operating compo-
nents of the range/cooktop.

• A window or air vent should be open slightly while using any

cooking appliance. Gas flames consume oxygen which must be
replaced to assure proper combustion.

NOTE TO CONSUMER

:

Have the installer or dealer show you where the main gas shut off
valve is located so that you will know how and where to turn off the
gas supply when necessary.

Table of Contents

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Illustration Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Parts Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7
Accessories / Extended Warranty . . . . . . . . . . . . . . . . .14 - 15
Cabinet & Counter/Recessed Bi-Fold - Cut Out Charts . . . .16
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

INSTALLATION

Installation must conform with local codes or in the absence of local
codes, with the American National Standard for Recreational Vehicles,
ANSI/A119.2 and Article 551, ANSI/NFPA 70. In Canada, installation
must conform with CSA Z240.4.2-M.

ƽ

WARNING

FIRE, EXPLOSION, BURN INJURY

CARBON MONOXIDE POISONING

• The cooking appliance must be completely separated and/or

sealed from other air moving or air consuming devices such as,
but not limited to, furnaces, microwave ovens, clothes dryers,
cooling fans and doors or drawers in common cabinets. Failure
to do so will affect the appliance(s) combustion air supply by
creating either a negative or positive draft.

• NEGATIVE DRAFT caused by air moving appliances may draw

the top burner flame down into or toward the cooktop resulting
in cooktop damage, burn hazard, explosion possibility and/or
carbon monoxide buildup.

• POSITIVE DRAFT may blow out the top burner flame during use

resulting in an explosion and/or fire hazard and/or injury to the
occupants of the vehicle.

DO NOT

operate the appliance in excessive windy conditions as

this may cause a negative or positive draft.

1. For proper operation of your cooking appliance:

THE HOUSING CABINET MUST BE:

• properly constructed.
• squared to the countertop and cabinet face

OPENING IN THE HOUSING CABINET MUST BE:

• level from side to side and front to rear

2. For ranges, the cabinet opening must be constructed so that no com-

bustible material can be placed next to the range sides. If there is a
gap between the range and an adjacent cabinet, the gap must be
closed prior to installing the range.

ƽ

WARNING

FIRE

• 30 inches is the

minimum vertical distance to combustible mate-

rial above the cooktop stove. This distance may be reduced by
using non-combustible construction in accordance with Table 2-
6.7.2 in ANSI A119.2.

ENGLISH

•Installation •Operation •Maintenance

Effective 1/16/08

LP GAS RANGE &

SLIDE-IN COOKTOPS

RV, CV, RA, CA (34) Models

PROTECTED BY U.S. PATENTS D397,909 AND 5,931,151

OTHER PATENTS PENDING

9

LITERATURE NUMBER

MPD 51381

Advertising
Table of contents