BRAND Hydraulics POR75 STYLE PILOT OPERATED RELIEF VALVE User Manual

BRAND Hydraulics Equipment

Advertising
background image

B

Certificate #02.002.1

ISO 9001:2000 WITH DESIGN

INSTALLATION SHEET FOR

POR75 STYLE PILOT OPERATED RELIEF VALVE

KEEP WITH PRODUCT UNTIL INSTALLED

ADDITIONAL SHEETS MAY BE PRINTED OUT FROM OUR WEBSITE

WWW.BRAND-HYD.COM

UNDER PRODUCT CATALOG SECTION


How do I adjust the relief setting?

First, remove the chrome hex plug with a 7/8”combination wrench, etc and set aside. This gives you access to the
relief set screw (5/16” hex). Turning the set screw clockwise 1 turn will increase the pressure ~300psi [20.7bar].


Can I paint my valve? – Painting valves is okay as long as the all ports are properly plugged.

Pipe thread sealant – Warranty is void when Teflon tape is used to seal pipe threads. This is because Teflon tape is a friction
reducing agent which allows customers to over-torque fittings. We recommend using a sealant that does not include friction
reducing agents i.e. Lead Plate.

B

R

A

N

D

HYDRAULICS

3/4" NPT

PRESSURE PORT

3/4" NPT

TANK PORT

S.N.

BRAND HYDRAULICS

1

4

" NPT PORT

IS PLUGGED

1.75" [44.5]

1.94" [49.2]

3.88" [98.4]

4.56" [115.8]

4.

56" [

1

15.

8]

1.62" [41.3]

0.87" [22.2]

1.75" [44.5]

CHROME

HEX PLUG

2x Ш0.27" [Ш6.8]

Note: ¼” NPT port can be vented to tank and used as an unloading valve as well as a relief valve.

Figure 1: Dimensional Data for Pilot Operated Relief valve in inches & [millimeters].

Revision 12-06

Advertising