Carolina Hotplate-Stirrer User Manual

Hotplate/stirrer operating manual

Advertising
background image

Operation Manual

Revised : January 2012



Hotplate/Stirrer

OPERATING MANUAL

This manual can be used for two models. One model,
the “Hotplate Stirrer”, has two knobs on the control panel
for separate control of heating and stirring functions.
The “Hotplate” has a single knob, to control the heating
function..

1.1 Getting Started


Thank you very much for purchasing our Hotplate / Hotplate
Magnetic Stirrer.

Your Hotplate/Magnetic Stirrer has been C E certified and
designed with durability, reliability, and safety in mind. It is
your responsibility to install this instrument in conformance
with local electrical codes. For safe operation, please pay
attention to the alert symbols through the manual.

This manual contains important operating and safety
information. You must carefully read and understand the
contents of this manual prior to operating this instrument.

Warning
Warning alert - possibility of personal injury

Caution
Caution alert - possibility of damage to the
equipment.

Note
Notes alert - pertinent facts and conditions.

Hot Surface
Hot surface alert - possibility of burning injury
by hot instrument surface

Explosive
Explosive alert - possibility of explosion by
high pressure.

1.2 Product Overview


These products are made with an excellent heat-resistant,
anti-corrosive aluminum casting body with a high quality
powder coating.

The ceramic coated and stainless steel top plate provides
excellent chemical resistance, especially against strong acids
or bases.

Unlike traditional hotplate/magnetic stirrers, these units have a
high precision speed control system. (from 60 to 1500rpm)
with a continuously smooth revolution pattern.

The technically advanced PCB board eliminates an electrical
overload and regulates energy distribution. The bearing type
motor maintains gentle revolution over the lifetime of the
equipment.


1.3 Parts and Functions



1.3.1. Control Panel







1 Temperature Controller
ON/OFF and Temperature Control
2 Heater Lamp
Red light Illuminates when heater is on
3 Speed Controller
ON/OFF and revolution speed control

4 Stir Lamp
Green light Illuminates when motor is on


1.3.2. Main Body







1 Power Cord
2 Fuse Holder

3 Standing Rod Position
4 Screw Position



1.4. Operation


Before Operation

1) Place Hotplate/Stirrer on flat and level surface.

2) Plug unit into power outlet. The voltage must correspond
to the voltage listed on the product name-plate

CAUTION : "Hot Surface. Avoid Contact."
The hotplate will remain hot without visual
indication for some time once the power has
been turned off.











































Operation

1) Temperature Control

- Turn temperature control knob clockwise, heat light
illuminates.
- Turn temperature control knob to adjust to the desired heat
position.


2) Stirring Speed Control

- Turn Speed control knob clockwise, stir light illuminates.
- Turn speed control knob to adjust to the stirring speed to
the desired position. (Increase speed slowly.)



1.5. Warning

1. Use a properly grounded electrical outlet

with the proper voltage and current
handling capacity as specified on the name-
plate.

2. Disconnect from power supply before

servicing or cleaning.

3. Always place the Hotplate Stirrer on a flat

and level surface.

4. Do not touch the top plate of the instrument

during operation. The hotplate will remain
hot without visual indication for some time
after you have turned the power off.

5. Do not use in the presence of flammable or

combustible materials; fire or explosion
may result. This device contains
components which may ignite such
materials.

6.

_

Replace the top plate immediately if

damaged by scratching or chipping. A
damaged top plate can shatter during use.

7. Do not use metal foil, metal containers,

sand baths or other insulating material on
the hot plate – This can cause damage to
the top plate and shock hazard can exist.

8. Do not remove or modify the grounded

power plug. Use only properly grounded
outlets to avoid shock hazard. The
instrument is not rated for use in
hazardous atmospheres.

9. Use caution when heating volatile samples;

top surface and element can reach the
“Flash Point Temperature”

of many

chemicals. These hot plates are not
explosion proof. Fire or explosion may
result. Unit contains components which
may ignite such materials.

10. Use appropriate hand and eye protection

_

when handling hazardous chemicals.

11.

Refer servicing of this instrument to

_

qualified personnel.

1.6. Trouble Shooting

Check

Trouble

Shooting

Not heating
Or
Not stirring

Check

power

Supply Cord

Plug firmly into
socket

Check Fuse

Replace Fuse

Contact customer service department.


SI Analytics GmbH

Phone: 800.334.5551

Fax: 800.222.7112

Email: [email protected]

/ 66 5001

1.3. Product Specifications

70-1013

70-1012

Type

Hotplate

Hotplate & Stirrer

Speed Range

N/A

60 to 1500 rpm

Temperature Range

80 degrees C to 380 degrees C

Controller

Electronic Solid State Controller

Material

Ceramic Coated Stainless Steel Top Plate

Dimensions

Plate

190 x 190 mm / 7.5 x 7.5 in

Overall

205(W) x 260(D) x 110(H) mm / 8.5(W) x 11(D) x 4.5(H) in

Power Consumption

Max. 500 watt, 3.0 amp

Electric Supply

120 or 220V, 50/60 Hz

1

3

2

4

1

3

2

4

Advertising
Table of contents