Z-Wave ZRW 113 Instructions, Series 200, Release 2.2

P/D 011008

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

0766-01

1

Z-Wave Radio Frequency (RF) Controlled, 120 VAC,

Isolated Contact Wall Mounted 3-Way Switch,

Series 200, Release 2.2

ZRW113

HomePro

RF Home Automation

ZRW113 WALL MOUNTED SWITCH

The ZRW113 Isolated Contact Wall Mounted 3-Way Switch is a component of the HomePro lighting control system.
Wire the Wall Mounted Switch in place of the standard wall switch according to the diagram above and program from
the Wireless Controller to operate loads. Inclusion of this Switch on the ZTH100 Wireless Controller menu allows
remote ON/OFF control of lamps connected.
This Wall Mounted Switch is designed to work with other Z-Wave enabled devices. Z-Wave nodes of other types can
be added to the system and will also act as repeaters if they support this function of repeating the signal received to
other modules in the system.
As part of a Z-Wave network, the ZRW113 will also act as a wireless repeater to insure that commands intended for
another device in the network are received. This is useful when the device would otherwise be out of the radio range
of the wireless controller.
There are no field repairable assemblies on this unit.. If service is needed, the unit must be returned where purchased.
DANGER! SHOCK HAZARD.! Read and understand these instructions before installing. This device is intended for
installation in accordance with the National Electric code and local regulations in the United States, or the Canadian
Electrical Code and local regulations in Canada. It is recommended that a qualified electrician perform this installation.
Make sure the load controlled by the switch does not exceed 5540 watts. For indoor use only. Retain instructions
for future use.

INSTALLATION

Wire the ZRW113 in place of a current wall switch according to the diagram above.
When used, AS101’s are required to be wired to the same line (or neutral) which is also wired to the master unit
as well as the load being controlled, and not wired to any other neutral. If multiple neutrals are tied together in one box,
separate the neutrals to preserve the integrity of the ZRW113 circuit. Caution! Do not wire unit “live” (with power on
the circuit) and do not allow the yellow wire to contact line voltage, neutral or ground or you will damage the device.
See the ZTH100 Wireless Controller operating instructions to add this module under the command of the Wireless
Controller.

Shown with supplied

Decora

TM

trim plate

Note: This module must be “Included in the Network” only
where it will be permanently installed
. The proper operation
of this node in the mesh network is dependent on it knowing its
location with respect to other nodes. You cannot “test bench”
configure this module, then install.

Advertising