Rl series feature string nomenclature, Base model, Model option a: cooling – AAON RL-240 User Manual

Page 13

Advertising
background image

13

RL Series Feature String Nomenclature

:

S

IZ

E

V

L

T

C

O

N

FI

G

A1

A2

A3

A4

B1

B2

B3

1A

1B

1C

1D

2

3

4

5A

5B

5C

6A

6B

6C

7

8

9

10

11

12

13

14A

14B

15

16

17

18

19

20

21

22

23

R L 1 0 0 3 0 B E 0 6 – 3 5 2 : B E B E – D 0 0 – Q F Y – P 0 A – 0 D B B 0 0 0 – 0 0 – 0 B B 0 0 AB 0 B

G

E

N

Model Options

Unit Feature Options

BASE MODEL

SERIES AND GENERATION
RL

UNIT SIZE
045 = 45 Nominal Tons
060 = 60 Nominal Tons
070 = 70 Nominal Tons
075 = 75 Nominal Tons
090 = 90 Nominal Tons
095 = 95 Nominal Tons
100 = 100 Nominal Tons
110 = 110 Nominal Tons
120 = 120 Nominal Tons
125 = 125 Nominal Tons
134 = 134 Nominal Tons
135 = 135 Nominal Tons
150 = 150 Nominal Tons
155 = 155 Nominal Tons
170 = 170 Nominal Tons
180 = 180 Nominal Tons
181 = 181 Nominal Tons
190 = 190 Nominal Tons
210 = 210 Nominal Tons
230 = 230 Nominal Tons
240 = 240 Nominal Tons

VOLTAGE
2 = 230V/3Φ/60Hz
3 = 460V/3Φ/60Hz
4 = 575V/3Φ/60Hz
8 = 208V/3Φ/60Hz

INTERIOR PROTECTION
0 = Standard
A = Interior Corrosion Protection










Model Option A: COOLING

A1: COOLING STYLE
B = Blow-Through, R-410A, Dual Circuited
C = Draw-Through, R-410A, Dual Circuited
D = Blow Through - R-134a Variable Capacity Oil-
Free Magnetic Bearing Centifugal Compressors
E = Draw Through - R-134a Variable Capacity Oil-
Free Magnetic Bearing Centifugal Compressors
F = Blow-Through AHU w/ Vestibule
G = Draw-Through AHU w/ Vestibule
H = Blow-Through AHU w/ Front Control Panel
J = Draw-Through AHU w/ Front Control Panel
M = Blow-Through AHU w/ End Control Panel
N = Draw-Through AHU w/ End Control Panel
R = Blow-Through, R-410A, Independ Circuited
S = Draw-Through, R-410A, Independ Circuited
7 = Blow-Through, R410A VFD Compatible
Compressors
8 = Draw-Through, R410A VFD Compatible
Compressors

A2: COOLING CONFIGURATION
0 = No Cooling
A = Air-Cooled Cond, 4 Row High CFM Evap
B = Air-Cooled Cond, 6 Row High CFM Evap
C = Air-Cooled Cond, 4 Row Low CFM Evap
D = Air-Cooled Cond, 6 Row Low CFM Evap
E = Evap-Cooled Cond, 4 Row High CFM Evap
F = Evap-Cooled Cond, 6 Row High CFM Evap
G = Evap-Cooled Cond, 4 Row Low CFM Evap
H = Evap-Cooled Cond, 6 Row Low CFM Evap
J = Water-Cooled Cond, 4 Row High CFM Evap
K = Water-Cooled Cond, 6 Row High CFM Evap
L = Water-Cooled Cond, 4 Row Low CFM Evap
M = Water-Cooled Cond, 6 Row Low CFM Evap
U = Chilled Water, 4 Row High CFM
V = Chilled Water, 4 Row Low CFM
W = Chilled Water, 6 Row High CFM
Y = Chilled Water, 6 Row Low CFM
Z = Chilled Water, 8 Row High CFM
1 = Chilled Water, 8 Row Low CFM
2 = Non-Compressorized, 4 Row High CFM Evap
3 = Non-Compressorized, 4 Row Low CFM Evap
4 = Non-Compressorized, 6 Row High CFM Evap
5 = Non-Compressorized, 6 Row Low CFM Evap

Advertising