Burkert Type 6518 User Manual

Operating instructions type 6518

Advertising
background image

Operating Instructions

Type 6518

Design:
3- and 5-way solenoid valve, internally piloted

Seal Materials and Fluids handled:
See Table 1.

Fluid and Ambient Temperature:
For Hazardous Locations Div. 1 (T4 rated)
Max. Ambient Temperature

104 °F (40 °C)

Max. Fluid Temperature

140 °F (60 °C)

For Hazardous Locations Div. 1 (T6 rated)
Max. Ambient Temperature

104 °F (40 °C)

Max. Fluid Temperature

140 °F (60 °C)

For Intrinsically Safe Apparatus for use in Class I, II and III,
Division 1 Hazardous Locations.
Max. Ambient Temperature

140 °F (60 °C)

Max. Fluid Temperature

140 °F (60 °C)

For Hazardous Locations Div. 2 and Ordinary Locations:
See Table 1.

Pressure Range:
Maximum inlet pressure see label on valve.

Installation:
Before installing valve ensure that piping etc. is free of foreign
matter (metal shavings, pipe sealing materials, welding scale
etc.). Installation as required but preferable with coil uppermost.
Installation in this position tends to prevent foreign matter
remaining in core tube (increased life). Do not put any loads on
coil unit.

PTFE tape is recommended for sealing ports. Mounting is
accomplished by means of four M4 x 8 mm tapped holes
located on the valve underside. Letters on valve body indicate
pressure port, exhaust and outlet of the valve.

Marking (example):

Body Material
PA

=

Polyamide

AL

=

Aluminium

Seal Material
PB

=

NBR and PUR

NBR

=

NBR

Circuit function
C = 3-way, Normally Closed
D = 3-way, Normally Open

Item No.

Voltage / Frequency / Power Consumption

Maximum Pressure

Approvals
The valve is either approved as

General Purpose valve for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 4

or

General Purpose valve for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 6

or

Intrinsically Safe Apparatus for Hazardous Locations

Class I, Division 1, Group A, B, C, D
Class II, Division 1, Group E, F, G
Class III, Division 1 and 2
Operating Temperature T 6

or

FM approved as

Nonincendive for Hazardous Locations
Class I, Division 2, Group A, B, C, D
Class II, Division 2, Group F, G
Class III, Division 1 and 2
Operating Temperature T 4

UL listed for General Purpose
CSA approved for General Purpose

See label on the valve.

Table 1

Seal Materials

Fluid

Temperatures [°F]

PB

Buna “N”

NBR

Air

Fluid Temp.

+ 10 to + 140

+ 10 to + 140

Ambient

+ 10 to + 140

+ 10 to + 140

Operating Instructions 0605/09_EN-EN_00800029

Voltage 12V or 24V

UL / UR valid with

class 2 power supply only

Advertising