HOMA Conversion Kit For Installation Of HOMA Pumps On Myers Rail Systems User Manual

HOMA Pumps

Advertising
background image

Publication

88PN3025A

Please Contact Technical Support At 203-736-8890 With Any Additional Questions

Please Be Prepared To Provide Pump Serial Number During Call

Page

1 of 1

Conversion Kit For Installation Of

HOMA Pumps On Myers Rail Systems

Use existing Myers pipe nipples and union to connect the discharge of the new

HOMA pump. Once the discharge is connected continue as follows:

• Thread locking cap onto the threads of the support column. Thread on loosely as the

cap will be used for adjustment.

• Slide the support column down through the upper bracket of the Myers rail system so

that the notch is over the handle of the HOMA pump.

• Insert the clevis pin through the hole in the support column and under the handle.

• Secure the clevis pin with the cotter pin. Do not forget to bend over the ends of

the cotter pin to keep it from falling out.

• Tighten the locking cap with a wrench taking up any slack.

• Tighten the two existing locking screws in the Myers upper bracket against the

support column. This will insure proper support of the pump.