6 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual

Celerity FC-42ES Adapter

The Celerity FC-42ES is a dual-channel host adapter
providing port density for Enterprise server and
workstation applications. With 4-Gb FC speeds of up
to 800 MB/sec. per channel, the FC-42ES supports
the most demanding application requirements.
Additionally the FC-42ES uses the latest in host
interconnect technology, PCI Express, a serial, high-
speed connection that supports aggregate throughput
up to 4 GB/sec. (x8 PCIe) full-duplex.
The FC-42ES is software compatible with existing PCI
and PCI-X products using the same device drivers as
other Celerity FC family products, simplifying user
installation and support. It is backward compatible with
existing 2-Gb and 1-Gb Fibre Channel infrastructure,
protecting existing technology.

Technical specifications

• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput

per channel

• Supports all FC topologies: direct fabric,

arbitrated loop and point-to-point

• ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-

AL2, FC-PLDA, FC-FLA

• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 Bytes; 8 @ 2 Kilobytes
• ATTO Advanced Data Streaming (ADS™)

Technology

Advanced FC Capabilities

• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb,

2-Gb and 1-Gb Fibre Channel

• Supports

target

and initiator modes

• Supports

Windows

FDMI and WMI

Host bus specifications

• x4 mechanical and x4 electrical PCI Express

Interconnect (RoHS compliant)

• Conforms to PCI Express Base Spec 1.0a
• Conforms to PCI Express CEM Spec 1.0a
• PCI Express to PCI/PCI-X Bridge spec 1.0

Environmental & physical specifications

• Operating temperature: 0-45ºC (32-113ºF)
• Storage temperature: -40 to 70ºC (-40 to 158ºF)
• Relative humidity: 10 to 90% non-condensing
• 100 lf/m (minimum) airflow recommended
• Conforms to PCI half height, half length form-

factor specifications

• 12V@ 4A (max.); 3.3V @ 1.5A (max.)
• Length:

5.6

inches

• Height: 2.712 inches
• RoHS

compliant

External connectivity

• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for

each channel

• 2 pluggable optical LC SFP transceivers

included

Software specifications

• Windows 7®, XP®, Vista®
• Windows Server® 2003, 2008
• Mac® OS X 10.4.x and up
• RedHat Enterprise Linux®

2.x (2.4.x kernels)

• RedHat Enterprise Linux®

3.x (2.4.x kernels)

• RedHat Enterprise Linux®

4.x (2.6.x kernels)

• RedHat Enterprise Linux®

5.x (2.6.x kernels)

• RedHat Enterprise Linux®

6.x (2.6.x kernels)

• SUSE

Linux

Enterprise® 8.x (2.4.x kernels)

• SUSE

Linux

Enterprise® 9.x (2.6.x kernels)

• SUSE Linux Enterprise® 10.x (2.6.x kernels)
• Fedora Core Linux® 7.x (2.6.x kernels)
• Fedora Core Linux® 8.x (2.6.x kernels)
• Fedora Linux® 9.x (2.6.x kernels)
• Solaris®

9.x

x86

• Solaris® 10.x x86
• VMware ESX Server® 3.5