8 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual

Celerity FC-42XS Adapter

The dual-channel Celerity FC-42XS host adapter
provides the highest available throughput for Fibre
Channel applications while protecting technology
investments via backward compatibility with existing
infrastructure.
With speeds of up to 800 MB/sec. per channel, the FC-
42XS is capable of supporting the most intensive data
applications.
To ensure a smooth transition path, the FC-42XS
leverages the existing Celerity FC software hardware
architecture, allowing ATTO to deliver industry-leading
quality and stable software architecture.

Technical specifications

• 2 independent Fibre Channel ports
• 4-Gigabit data transfer rates per channel
• 800 MB/sec. maximum full-duplex throughput

per channel

• Supports all FC topologies: direct fabric,

arbitrated loop and point-to-point

• ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-

AL2, FC-PLDA, FC-FLA

• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 8 @ 512 bytes; 8 @ 2 Kilobytes
• ATTO Advanced Data Streaming (ADS™)

Technology

Advanced FC capabilities

• Supports SNIA HBA API
• On-demand automatic negotiation among 4-Gb,

2-Gb and 1-Gb Fibre Channel

• Supports target and initiator modes

• Supports

Windows

FDMI and WMI

PCI bus specifications

• 64-bit, 133 MHz PCI-X
• PCI-X 1.0a compliant
• PCI

2.2

compliant

• 3.3V PCI signaling only

Environmental & physical specifications

• Conforms to PCI low profile form factor

standards

• Length: 6.600 inches
• Height: 2.536 inches
• Operating temperature: 0-45ºC (32º-113ºF)
• Storage temperature: -40º to 70ºC (-40º to

158ºF)

• Relative humidity: 10 to 90% non-condensing
• 3.3V@ 1.5A (max.)
• 100 lf/m (minimum) airflow recommended
• RoHS

compliant

External connectivity

• Easy-to-install full height connection plate
• External LEDs for on-line and speed status for

each channel

• 2 optical LC SFP transceivers included

Software specifications

• Windows 7®, XP®, Vista®
• Windows Server® 2003, 2008
• Mac® OS X 10.4.x - 10.5.x
• RedHat Enterprise Linux®

2.x (2.4.x kernels)

• RedHat Enterprise Linux®

3.x (2.4.x kernels)

• RedHat Enterprise Linux®

4.x (2.6.x kernels)

• RedHat Enterprise Linux®

5.x (2.6.x kernels)

• SUSE

Linux

Enterprise® 8.x (2.4.x kernels)

• SUSE

Linux

Enterprise® 9.x (2.6.x kernels)

• SUSE Linux Enterprise® 10.x (2.6.x kernels)
• Fedora Core Linux® 7.x (2.6.x kernels)
• Fedora Core Linux® 8.x (2.6.x kernels)
• Fedora Linux® 9.x (2.6.x kernels)
• Solaris®

9.x

x86

• Solaris® 10.x x86

Advertising