Chapin 1831 User Manual

Warning, Pressurizing and spraying, Pressurizing and spraying, continued

Advertising
background image

Hazard: Improper use or failure to follow instructions can result in explosive failure

causing serious eye or other injury.

For safe use of this product you must read and follow

all instructions. Do not leave a pressurized sprayer in the hot sun. Heat can cause pressure

build-up. Do not store or le

ave solution in tank after use. Always wear goggles, gloves, long

sleeve shirt, long pants and full foot protection when spraying. Never use any tool to remove

pump if there is pressure in sprayer. Never stand with face or body over

top of tank when

pumping or loosening pump to prevent ejecting pump assembly and/or solution from strik-

ing and injuring you. Never pressurize sprayer by any means other than the original pump.

Do not attempt to modify or repair this product except with original manufacturer’s parts.

Never spray flammable materials or heat, pressure, or gas producing chemicals. Always

read and follow manufacturer’s instructions before use with this sprayer as some chemi-

cals may be hazardous when used with this sprayer.

WARNING!

Sk-1113-1

Note:

Your particular sprayer may not include all parts pictured above.

Nota:

Es posible que este pulverizador en particular no incluya todas las partes que se ilustran arriba.

Remarque :

Votre pulvérisateur particulier pourrait ne pas inclure toutes les pièces illustrées plus haut.

Repair Parts Kit Gaskets and Seals (not included),

Juego de piezas de reparación, empaquetaduras y juntas (no incluido)

Kit de pièces de réparation, joints et garniture d’étanchéité (non inclus)

6-4627

Printed in USA

1. Hose to Tank

2. Nozzle

Make sure hose is pushed all the way to

the tank. Make sure hose clamp is tight

and below the hose barb. Turn clockwise

with a screwdriver to tighten.

1) Do: Check tightness of hose nut to be sure hose is securely attached to the tank outlet.

2) Do: Inspect hose for deterioration, cracks, softness, or brittleness. If any of these

conditions are found, replace hose before using. Replace with original manufacturer’s

parts only.

3) Do: Remove pump (see Filling, Pressurizing and Spraying Instructions), inspect interior

and exterior of tank for signs of deterioration of body and bottom. Any sign of

deterioration indicates possible tank weakening and could result in explosive bursting

under pressure. If any of these signs are found, discard tank immediately and replace.

Do not attempt to patch leaks, etc., as this could result in serious injury.

4) Do: Follow Filling, Pressurizing and Spraying Instructions, except use water only.

5) Do: Pump plunger 10-20 strokes and inspect for leaks.

6) Do: Direct shut-off away from you and open to make sure discharge is not clogged.

7) Do: If unit passes this test, release pressure (see Pressure Releasing Instructions), empty

tank, and proceed with Filling, Pressurizing and Spraying Instructions.

3. Pre-Use Check

4. Filling

1) Do: Turn pump handle counterclockwise and remove pump

2) Do: Prepare spray solution following all directions and safety warnings on

chemical label.

3) Do: Fill tank to no more than the proper gallon marker. Do NOT: overfill to

accommodate pump.

4) Do: Check pump to make sure that no grass or dirt is stuck to barrel. Replace pump in

tank and tighten securely.

WARNING:

Handling the brass parts of this product will expose

you to lead, a chemical known to the State of California to cause

birth defects and other reproductive harm. Wash hands after

handling.

2-1032 (A) R0209

8. Care, Storage and Maintenance

1) Do: Rinse tank thoroughly with water only, empty, refill with water. Follow Filling,

Pressurizing and Spraying Instructions, except pump unit only 8-10 strokes.

2) Do: Open shut-off and allow water to run through discharge assembly.

3) Do: Release pressure (Follow Pressure Release Instructions), remove pump and

empty sprayer.

4) Do: Store sprayer tank upside down, with pump removed, in a warm dry location.

5) Do: Periodically oil pump by dropping 10-12 drops of light oil down pump rod

through opening in cover.

7. To Release Pressure

1) Do: With pump facing away, turn locked handle counterclockwise until air begins to

escape. Stop turning handle when you hear air escaping.

2) Do: Stay away from the sprayer until all air has escaped.

Hose Barb

Attach nozzle to shut-off handle or extension wand.

1A

2A

2B

Parts, Piezas, Pièces

6-6136

Hose

Manguera

Tuyau

6-1866

Shut-off Handle

Mango de cierre

Poignée du robinet

6-6000

Nozzle

Tobera

Buse

6-3337

Strap

Correa

Sangle

6-7711

Extension wand,

Vara de extensión, Rallonge

For constant spraying, push down on shut-off

handle and move locking mechanism away

from you. To release, squeeze handle and move

the locking mechanism back towards you.

6. Fatigue-Free Spraying

Congratulations!

You have just purchased a quality Chapin product.

Register Your Sprayer Online @ www.chapinmfg.com
Questions?

Do Not Return To Store.

Call us @ 1-800-950-4458 or www.chapinmfg.com

¡

Felicitaciones!

Usted acaba de adquirir un producto de calidad Chapin.

Registre su pulverizador en línea en www.chapinmfg.com
¿Preguntas?

No regrese a la tienda;

llámenos al 1-800-950-4458 o visite www.chapinmfg.com
Félicitations!

Vous avez acheté un produit de qualité Chapin.

Enregistrez dès que possible votre pulvérisateur en ligne à l'adresse suivante:

www.chapinmfg.com
Questions ?

Ne retournez pas au magasin.

Appelez-nous 1-800-950-4458 ou visitez le www.chapinmfg.com

6A

TO LOCK HANDLE:

Push handle down to depress coil spring and turn handle 1/4 turn

clockwise, then allow handle to raise into lock position.

5. Pressurizing and Spraying

5A

5B

TO RELEASE HANDLE: Push down to depress coil spring

and turn handle counterclockwise 1/4 turn, then lift handle.

Pump until you feel resistance.

TO LOCK PUMP: Place pump prongs down into slots in funnel,

turn clamp clockwise to furthest position under bottom slot, then

turn handle clockwise until tightly locked and sealed in place.

TO UNLOCK PUMP: Turn handle counterclockwise until

3-prong clamp is loose. Then rotate clamp counterclockwise to

stop and lift out.

5C

5D

5. Pressurizing and Spraying, continued

5E

5F

Advertising