2 features, 3 how is the ultra isc used, 4 ce emc responsibility – Cleveland Motion Controls ULTRA ISC SERIES SLIM CELL TRANSDUCER REV AA User Manual

Page 10: Eatures, Ow is the, Ltra, Esponsibility

Advertising
background image

U

LTRA

ISC

S

ERIES

S

LIM

C

ELL

T

RANSDUCER

MAN-70434-0

R

EV

AA

1.2 F

EATURES

Ultra ISC tension transducer features are:

 Factory Calibration promotes interchangeability

 Tension controller observation of individual loadcell signals provides increased opportunity

for advanced diagnostics and calibration.

 Self contained precision excitation circuit eliminates the need for the expense and

complication of remote sense

 24V supply has reverse polarity protection

 Analog output buffer designed to accommodate capacitive cable loads.

 Floating strain-gage and output stage allows “stacking” ISC outputs for simple summing.

 Sealed enclosure and M12 connector provide environmental protection

 Industry standard M12 allows use of readily available molded cordsets

1.3 H

OW IS THE

U

LTRA

ISC

U

SED

The Ultra ISC load cell has been developed for those customers who desire to send the amplified
transducer signal directly into their Controller, PLC, PAC, Drive, or Local I/O.

The signal outputs are zeroed, scaled, and summed (if a pair of transducers is used) by
software. It is the responsibility of the customer to write this software.

The Ultra ISC load cell is shipped preset from CMC with 0 volts representing no load, and 10 volts
representing the 100% full rating of the transducer. (Example: A 100 lb Ultra ISC transducer with no
load outputs 0 volts. With a 100 lb. load the output is 10VDC when loaded in one direction and -
10VDC when loaded in the opposite direction.)

1.4 CE

EMC

R

ESPONSIBILITY

The Integrated Signal Conditioning (ISC) Amplifier MO-13333-10ISC Ultra Series module
embedded in the transducer can be considered a component performing a direct function and
therefore is subject to the provisions of the EMC Directive.

To assist manufacturers, suppliers, and installers of relevant apparatus, this amplifier module is
compliant to EN61326:1997 when installed according to these instructions. Manufacturers,
suppliers, and installers of relevant apparatus may use this compliance as a contributing basis for
their own justification of overall compliance with the EMC Directive.

Before installing the Ultra Series ISC Amplifier you must clearly understand who is legally
responsible for conformance with the EMC Directive. Misappropriation of the CE mark is a criminal
offense.

P

AGE

10

OF

42

Advertising