1.0 GENERAL INFORMATION

1.1

RECEIVING AND UNPACKING

Handle and unpack the equipment carefully.
Immediately upon arrival, check the shipment against the
packing list. Any damage should be reported
immediately to the carrier and to the nearest CMC®
representative.

Equipment which will not be installed immediately should
be stored in a clean, dry location. Precautions should be
taken to prevent moisture, dust and dirt from
accumulating in storage and installation area.

1.2

PRECAUTIONS

1.2.1 Shipping - It is recommended that the sensing roll
be removed when the machine is shipped with the
transducers mounted. The shock and vibration
transmitted to the transducers by the sensing roll during
transporting can damage them.

1.2.2 Handling - An impact such as dropping the
transducer or a sharp blow to the transducer can
damage it. The unit should be completely surrounded by
a soft foam cushion when being transported.

1.2.3 Overloading - Repetitive overloading above the
maximum working force, shock or severe overloading
should be avoided because they can damage the unit.

1.2.4 Overvoltage - The excitation voltage should not
exceed 10 VDC or AC (RMS). Excessive voltage can
destroy the semiconductor strain gages.

The voltage between the gage and beam or base
(ground) should not exceed a peak of 50 volts.
Exceeding this voltage can cause an insulation
breakdown between the gage and the beam.

1.3

SPECIFICATIONS

Gage Resistance

- 220 ohms per leg nominal

Gage Factor

- 100 nominal

Excitation Voltage

- 5.6 VDC or VAC (RMS)

nominal. Not to exceed
10 VDC or VAC (RMS)

Output Signal
at Rated MWF

- 20mV/V, 30mV/V

(Alum, Steel)

Size 1 Steel, Size 2 Steel

Output Impedance

- Approximately 850 ohms

at 25

EC

Size 1 Aluminum

- Approximately 120 ohms

at 25

EC

Required Input
Impedance of
Tension Amplifier

- 5000 ohms

Insulation Breakdown
Voltage Gage to Beam

- 50 volts peak

Operating Temperature

- 0

EF to +150EF