Accessory and relay connections, Battery installation, Wiring – Chamberlain MADCBB User Manual

Page 10: Relay output k1 - (optional)

Advertising
background image

10

ACCESSORY AND RELAY CONNECTIONS

These terminals will provide battery backed power to 24 Vdc devices and are located
at the bottom of the control board at J4 terminals 1 and 2. Terminal 1 is 24 Vdc (+)
and number 2 is 0 Vdc (-). Peripheral CLASS 2 low voltage devices that require
24 Vdc power maybe connected here (500 ma. maximum).
EXAMPLE: Vehicle detector, radio receiver.

WIRING »

ACCESSORY AND RELAY CONNECTIONS + BATTERY INSTALLATION

24VAC XFM

ACC+

PWR

C

NC NO

Aux Relay

DC

1

1

K1

D11

D12

R13

D14

U19

J4

F3

J1

ACC–

BAT–

BAT–

MOV

BAT+

+

+

Black Lead

Jumper

12 VDC Battery

12 VDC Battery

Red Lead

BATTERY INSTALLATION

CONNECTING THE BATTERY LEADS - ALWAYS CONNECT AC POWER BEFORE
INSTALLING BATTERIES.

Connect AC power BEFORE installing batteries.

Install two new, fully charged 12 volt DC batteries on shelf next to motor.

Connect red lead from the operator control board to the positive (RED +)
terminal of one battery.

Connect the black lead from the operator control board to the (BLACK -)
terminal of the OTHER battery.

Connect the jumper (provided) between the remaining terminals of each
battery if one is not already in place.

IMPORTANT: Do not run operator without installing the batteries.
Replace batteries in pairs using LiftMaster MBAT or 29-NP712 batteries. Failure to
install batteries correctly will cause damage and will not be covered by warranty.

Relay Connection Terminals on the J4 Terminal Block

24 Vdc (+)

0 Vdc (-)

S1-6 S1-8

RESULT

OFF

OFF

Relay will fire (latch) when gate is not closed.

ON

OFF

Relay will fire when arm is pushed up off of limit
switch (use with slip clutch option) and fires relay
when a tail-gate is detected by the close loop -
ANTI TAIL-GATE ALARM.

OFF

ON

Relay will pulse relay when arm reaches full
open position.

ON

ON

Relay will only pulse when input is given to J5
1,2,3 inputs. (Refer to pages 14-15.)

AUX LIMITS

1

J2

1

R1

S1

D8

1

2

S2

1

2

D1Ø

RELAY OUTPUT K1 - (OPTIONAL)

S1-6

S1-8

S1 DIP Switch Block

1

2
3

4

5

The K1 Relay (optional) and terminal strip (J1) are used for auxiliary devices such as
Counters, Alarms,Buzzers, and SAMS (Sequence Access Management System).