INSTALL THE K1 AUXILIARY RELAY AND CONNECTOR AT MEGA ARM
CONNECTED TO THE ACCESS DEVICE

1. Press the relay into the K1 location ensuring the pins are properly aligned.
2. Press the connector into the J1 connector pins.

INSTALL THE K1 AUXILIARY RELAY AND CONNECTOR AT THE SECOND

1. Press the relay into the K1 location ensuring the pins are properly aligned.
2. Press the connector into the J1 connector pins.

WIRE THE CONNECTIONS BETWEEN THE OPERATORS

1. Connect the Normally open output (NO) of the K1 relay on the trap operator to

the OPEN input (J5 - term#2) of the second operator.

2. Connect the common output (C) of the K1 relay of the trap operator to the

common of the second operator (J5 - term#12).

3. Connect the Normally open output (NO) of the K1 relay on the second operator

to the INTERLOCK input of the trap operator (J5 - term#8).

4. Connect the common output (C) (J5 - term#12) of the second operator to the

common of the trap operator (J5 - term#12).

SET THE DIP SWITCHES AT THE TRAP OPERATOR

1. Set switch bank S1 to 00100001 where 1 is up and 0 is down.
2. Set switch bank S2 to 00100010 where 1 is up and 0 is down.

SET THE DIP SWITCHES AT THE SECOND OPERATOR

1. Set switch bank S1 to 00100000 where 1 is up and 0 is down.
2. Set switch bank S2 to 00100010 where 1 is up and 0 is down.

S1

1

ON

2 3 4 5 6 7 8

1

ON

2 3 4 5 6 7 8

Close
Loop

S2

OFF

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

ON

OFF

OFF

1

ON

2 3 4 5 6 7 8

1

ON

2 3 4 5 6 7 8

S1

S2

OFF

OFF

ON

ON

ON

ON

ON

ON

OFF

OFF

ON

ON

ON

ON

ON

ON

RECONNECT THE POWER AND TEST

1. Reconnect the DC power by replacing the neutral (Black) wire to the battery

terminal.

2. Reconnect the AC Power to the operator.
3. To test, activate the following sequence of inputs:
• Open the trap gate using the access device.
• When the trap gate is open, activate the close loop on the trap operator.

The trap gate will close and the second gate should open.

• When the second gate is open, activate the close loop on the second

operator. The second gate should close.

Mega ARM Operator

Trap Operator

S1

S1

S2

S2

TRAP CONFIGURATION

Must use trap kit. See Mega Arm Options Parts List

Mega Arm

Mega Arm Trap

Close
Loop

Close Loop Trap

Close Loop
Trap

Card Reader
Tele-entry
Radio Control

S1-6 OFF
S1-8 OFF

S1-6 OFF
S1-8 ON

C NC NO DC

C NC NO DC

Opener

Common

Interlock

OPEN

Trap

TES

TRAP SET UP

C

K1

MA

MA

ADDITIONAL FEATURES »

TRAP INSTRUCTIONS

TRAP INSTRUCTIONS