TRANSMITTER INSTALLATION:

1- Remove lid from top of the MWCT04 Transmitter to reveal mounting holes.

Position the Transmitter near the bottom of the door and mark the mounting
hole locations.

2. Remove the Transmitter from door, drill holes and mount the Transmitter with

screws supplied. NOTE: DO NOT drill any holes in the transmitter box.
Only use holes in the 4 corners of the box. Any additional holes in the transmitter
box will cause water to enter and a loss of warranty.

3- Loosen wire fitting nut and feed the 2 or 4 wire sensing edge leads into the Transmitter housing trimming off excess wire.

4- Attach the 4-lead wires to the large green two-part terminal block connector as White, White, Black, Black. If a 2-lead wire

connection is appropriate, connect them to the middle terminals, i.e. none, White, Black, none.Tighten the wire fitting nut
to assure water tight connection.

5- Adjust Dip Switches: 1= Address Selector 2= Address Selector 3= Address Selector 4= Address Selector

5= OFF for 4-wire edges, ON for 2-wire 10K

terminal edges 6= Edge Input ON=N/O OFF= N/C 7= Always OFF

8= OFF for Normal Operations, ON for Test Mode (transmitter always “ON”)

NOTE: the four DIP address switches must be set identically on the transmitter and receiver.

6- Be sure that the battery strap is connected and insert 9 Volt battery into the lid of the unit, and replace the lid.

The Green LED light should light up briefly, indicating that the unit is functioning properly.

The Communicator

II

Model # MWCK04

Wireless Transmitter/Receiver Kit

Installation Instructions

RECEIVER INSTALLATION:

1- Hold the MWCR04 Receiver in the mounting position near the operator: mark and drill mounting holes.

2- Attach a 24VAC (at least 100mA) source to the Red & Black wires. A 24 VDC source may also be used with Red to positive

(+) and Black to negative (-). When using 24 VAC, check to see if one
leg is connected to the operator case. If connected to the case, connect
that leg to the Black wire of the receiver.

3- Connect the White wires to the Safety Edge input for the motor operator.

The output relays will bear a resistive load of 1A at 24VAC.
The state of the relay is shown with a Yellow LED. The LED is

illuminated when the channel is in a SAFE operating condition

and will go out under fault condition. Relay contacts can
be selected N/O or N/C by moving jumpers (shunts)
inside the enclosure.

4- Adjust Dip Switches: 1= Address Selector 2= Address Selector

3= Address Selector 4= Address Selector 5= OFF for Standard
operation (all faults and safety edge activity activate the operator’s
safety edge input)

5- Mount the Receiver near the operator using the 2 screws supplied.

Take care to make sure the rigid wire antenna completely extends past

any metal of the operator enclosure.

6- Attach Coax Rigid Wire antenna. (The unit will not work unless the rigid antenna is properly attached.)

MILLER EDGE, INC. • P.O. Box 159 • West Grove, PA 19390 • 610-869-4422 • Fax: 610-869-4423 • 1-800-220-3343 • www.milleredge.com

MILLER EDGE, INC. • 6809 South Harl Avenue • Suite A • Tempe, AZ 85283 • 480-755-3565 • Fax: 480-755-3558 • 1-800-887-3343

Part # 400-MW-002
Rev. 002 / 8-18-10

WARNING!

Proper Mounting Location on Bottom Bar

Edge Sensor

Proper location
of a MWCR-04
Receiver with
Antenna

Proper location
of the MWCT-04
Transmitter on
the Bottom Bar

Typical Installation

TO REDUCE RISK OF SEVERE INJURY OR DEATH; READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS

TO PREVENT ELECTROCUTION: DISCONNECT POWER AT FUSE BOX OR CIRCUIT BREAKER AND DOOR OPENER BEFORE WIRING PERMANENTLY.

IMPROPER WIRING COULD CAUSE ELECTROCUTION OR DAMAGE TO CIRCUITRY. FOLLOW ALL LOCAL BUILDING CODES AND NATIONAL ELECTRICAL CODES.

WARNING!

U.S. Patent # 7,123,144