LEADER PHABRIX SxE JITTER_EYE ANALYSIS User Manual

Phabrix, Sxe jitter / eye analysis, Broadcast excellence

Advertising
background image

The analysis option for the PHABRIX

®

SxE adds an additional

jitter screen plus enhancements to the eye display and is

focussed toward broadcast manufacturers who have a need for

high end analysis tools.

HISTOGRAMS

Histograms give statistical information which can be used to

accurately measure rise time, fall time and amplitude. These

automatic accurate measurements can then be logged for

extended periods of time. Measurements like rise time and fall

time are notoriously difficult to make with SDI signals and here the

PHABRIX SxE excels, providing user friendly automatic

measurements even in the presence of excessive jitter.

DECADE FILTERS

In addition to the standard timing and alignment jitter filters,

decade filters are provided allowing an engineer to analyse the

frequency content of any jitter present. The number of eyes

displayed is adjustable from one eye up to one frame of eyes – a

useful feature for detecting source related power supply problems.

MULTIPLE EYE DISPLAY

Multiple eye selection also enables analysis when serialiser jitter

is present: Products process video in either a 10 or 20 bit parallel

data domain which is subsequently transmitted as a single bit

serial data stream. By triggering every 10 or 20 eyes you can

reveal repetitive parallel/serial clock domain jitter in equipment

being analysed.

FULL SCREEN JITTER DISPLAY

The separate jitter analysis screen incorporated into the advanced

option enables the engineer to analyse the nature of jitter present

using a graph of jitter versus time. Again, the decade filters are

present and the time base can be adjusted from 1 line through to

1 frame. By analysing jitter in this detailed way an engineer can

determine if a signal is in or out of specification and also get a feel

for where any problems lie. A spiky waveform could indicate

power supply noise and these visual clues aid the diagnosis.

Vertical gain and horizontal magnify controls are provided to help

further identify problems.

ORDERING INFORMATION

Option code

PHSXOEA (SxE ONLY)

broadcast excellence

PHABRIX®

®

EYE AND JITTER ANALYSIS

HISTOGRAMS

DECADE FILTERS

MULTIPLE EYE DISPLAY

FULL SCREEN JITTER DISPLAY

AUTOMATIC EYE MEASUREMENTS

AUTOMATIC JITTER MEASUREMENTS

APPLICATIONS

R&D DEPARTMENTS

SYSTEM INTEGRATORS

SUPPORT ENGINEERS

AVAILABLE FOR

PHABRIX® SxE

FEATURE HIGHLIGHTS

SxE JITTER / EYE ANALYSIS

Full screen display of the jitter wave form with access to decade filters.

Automatic measurements via thermometer readings.

The SxE analysis display providing multiple eye

selection, histograms and decade filters.

Revision

02/14

* Specifications and features described herein are subject to change without prior notice.

Please consult our website www.phabrix.com for the latest data.
PHABRIX is a registered trademark.

Represented in the Americas by

LEADER INSTRUMENTS CORPORATION

Fullerton, CA 92831

1501 E. Orangethorpe Avenue, Suite 140

Toll Free 1-800-645-5104

[email protected]

Tel 1-714-527-9300

www.LeaderAmerica.com

Advertising