Liquid Controls Pulse Output Device POD User Manual

Pulse output device (pod), Features & benefits, General information

Advertising
background image

Pulse Output Device (POD)

Electronic Pulse Output for Positive Displacement Metering

• Glandless drive
• No dynamic seals to fail or leak
• Unscaled pulse output
• Easily adapts to remote totalizers, batch controllers,

computers, PLC’s and other pulse receiving devices.

• No amplifier or signal conditioner required
• Wetted parts 316 stainless steel or equivalent

Features & Benefits

Pulse Output Device (POD)

General Information

The Liquid Controls Pulse Output Device (POD)
converts the rotary motion of Liquid Controls
Positive Displacement Flowmeters into electronic
pulses that equal the volumetric measurements of
the meter.
The POD mounts directly to the front cover of the
meter in place of the packing gland. The motion of
the meter’s blocking rotor is magnetically coupled
through a stainless steel wall to the electronics
compartment of the POD. This eliminates the
dynamic seal of the packing gland and isolates the
electronics from the process fluid in the meter.
The electronic pulses generated by the POD
is easily adapted to a wide variety of electronic
monitoring devices and control equipment.

www.lcmeter.com

• Meets current environmental standards: Weights &

Measures; NEMA 4X; Class I, Div. 1 & 2, Groups C &

D; DNV 11 ATEX 01600X and IECEx DNV 11.0012X

• 350 PSI (24 BAR) working pressure rating
• Burst pressure exceeds 1,750 PSI (121 BAR)
• ½" NPT conduit port with a removable screw terminal

block

Specifications

Voltage

• 9 to 30 VDC; POD5 is 5 VDC

Current supply

• 50 mA maximum

Output Signal Resolution

• 100 pulses per channel per revolution,

unscaled see table

Square Wave

• Single channel output channel A or

channel B

• Quadrature channel output channel A

and channel B

Pulse Timing

• Nominal 50% on and 50% off

Rise/Fall Time of Pulse

• <5 µs

Operating Temperature Range

• -40 to 176 °F (-40 to 80 °C)

Output

• Current sinking100 mA maximum in

“ON” state

• V+ supply @ 2.2 K

Ω in “OFF” state.

• Optional Open Drain FET (Field Effect

Transistor).

• FET rating (drain to source voltage) 30

VDC maximum

Humidity Range

• 0-100%, non-condensing

Shock

• 50 Gs for 10 ms

Vibration

• 1 G at 10-150 Hz

Pulse Transmission Distance

• 5,000 feet (1,524 meters)

Electromagnetic Compatibility (EMI,

RFI, etc.)

• EU Directive 2004/108/EC (EMC)
• IEC 61000-4-2
• IEC 61000-4-3
• IEC 61000-4-5
• IEC 61000-4-6
• IEC 61000-4-17
• IEC 61000-4-29
• IEC 61000-6-3
• ISO 7637-2

Advertising