Lightronics FL2020D User Manual

Fl-4020 fluorescent ballast controller

Advertising
background image

Page 1 of 5

FL-4020 FLUORESCENT BALLAST CONTROLLER

Version 1.0

OWNERS MANUAL

10/06/2005

www.lightronics.com

Lightronics Inc

509 Central Drive Virginia Beach, VA 23454

Tel 757 486 3588


PRODUCT DESCRIPTION

The FL-4020 is a four channel controller add on product for the AR-1202 Architectural dimmer. It provides control
of dimmable fluorescent lighting ballasts. The FL-4020 provides four 2400 Watt channels of fluorescent dimming
which is interfaced to the AR-1202 control circuitry. The AR-1202 uses its four auxillary channels (13 – 16 ) to
control the FL-4020. Dual SCR “zero crossing” switching is used to control the switched hot lines.

The FL-4020 is supplied in two versions:
FL-4020A: Controls ballasts which use a switched 120 VAC “hot” and a dimmed 120 VAC as a control signal.
FL-4020D: Controls ballasts which use a switched 120 VAC “hot” and a 0-10 VDC dimming control signal.

INSTALLATION

WARNING

MAKE CERTAIN POWER IS REMOVED FROM THE FEED CIRCUITS

BEFORE YOU BEGIN INSTALLATION.




The unit should be wall mounted close to an AR-1202 dimmer. The unit may be "stood off" from the wall (aprox.
1") to assure clear airflow across the rear heat sink surface. A 120VAC 20 Amp power input must be provided for
each dimming channel. Each channel may control multiple ballasts as long as the channel load does not exceed
2400 Watts. The internal low current electronic circuitry is powered, via a 1/2 Amp 250VAC fast blow fuse, by the
H1 input power connection.

REQUIREMENTS FOR THREE PHASE OPERATION:
In order to provide zero crossing switching, the AR-1202 uses a specific phase sequence when operated with 3
phase power. The sequence convention must also be adhered to when connecting the FL-4020. The phase
connected to the AR-1202 H1 power input terminal must also be used for channels

1 and 4 of the FL-4020. The

AR-1202 H2 phase must be used for FL-4020 channel 2. The AR-1202 H3 phase must be used for FL-4020
channel 3. The table below summarizes this requirement.

POWER PHASE

AR-1202 CHANNEL

FL-4020 CHANNEL

H1 13

13

H2 14

14

H3 15

15

H1 16

16


TYPICAL CONNECTION SCHEME

SWITCHED 120VAC

SWITCHED 120VAC

SWITCHED 120VAC

SWITCHED 120VAC

Control Signal

Control Signal

Control Signal

Control Signal

CH 13

CH 16

CH 15

CH 14

Channel 16 Control

Channel 15 Control

Channel 14 Control

Channel 13 Control

AR-1202

User supplied

120VAC feeds from

circuit breaker

panel

To

Lamp

Ballasts

FL-4020














Control Signal may be either 0 - 10 VDC

OR

120VAC Dimmed hot





Advertising