Features and Benefits

Ī

Creates wide array of communi-
cation options for UPSs

Ī

Acts as the framework for proto-
col conversion via compatible X-
slot cards to:

-Modbus

-SNMP

-HTTP

Ī

Compatible with X-slot cards

-Modbus Card (one included)

-ConnectUPS-X SNMP/

Web Adapter

-ConnectUPS-M SNMP Module

-Single Port Serial Card

-Multi-Server Card

Ī

Supports wide range of UPSs

-Powerware 5115

-Powerware 5125

-Powerware 9120

-Powerware 9125

-Powerware 9170+

-Powerware Prestige 9

-Powerware Plus 12, 18, 36

-Powerware 9315 Reverse

Transfer Module

-Powerware 9315 Hot Sync

Parallel Redundant Module

-Powerware 9315 Hot Sync

Parallel Capacity UPM

-Powerware 9315 Hot Sync

Parallel Capacity SBM

Ī

Flexible mounting options

Ī

Redundant power inputs

With network complexities increasing, a variety

of communication methodologies may be used

to monitor critical equipment on the network.

At the same time, the availability of reliable

power is becoming more important for

maintaining data integrity. The net effect of

these factors is the need for flexibility of

communication methods with strategic

equipment including an Uninterruptible Power

System (UPS). With the Powerware Expansion

Chassis, users may easily configure a UPS-based

power protection system that supports the

chosen network protocol.

Communication Card Options/

Protocol Conversion

The Expansion Chassis is a three-slot peripheral

device that expands communication methods for

a UPS through its support for X-slot™cards. It

comes preconfigured with a card that conforms

to the Modicon

®

Modbus

®

‚ protocol. The Modbus

Card serves as the integral communications

controller for the other two slots.

The Modbus card and its associated Profiler

software utility allow easy integration into a

Building Management System (BMS). Key facil-

ities personnel may monitor power conditions in

real-time through this configuration.

Two additional slots are available for use with

any of the following cards:

Ī

ConnectUPS™-X SNMP/Web Adapter – monitor

via SNMP or the Web

Ī

ConnectUPS-M SNMP Module – monitor via

Simple Network Management Protocol (SNMP)

Ī

Single Port Serial Card – connect an additional

server for monitoring and graceful shutdown

Ī

Multi-Server Card – connect up to three

servers for monitoring and graceful shutdown,

supports load segment control and RS-232

signals for low battery and AC Fail

Ī

Modbus Card – connect to another Modbus

Network, monitor via BMS

The Expansion Chassis and associated cards

effectively act as a protocol converter easily

integrating the UPS into open architecture

management systems.

Flexible Mounting

The Expansion Chassis may be placed on or

close to the associated UPS using the included

mounting feet. The kit includes brackets for

rack and wall mounting.

Advertising