5installation, Network adapter, 100m – ALFA Dual Speed Hub ADH32SB User Manual

Page 12

Advertising
background image

5

5

Installation

1. Operating Environment

These Dual Speed Hubs must be installed and operated within the limits
of specified operating temperature and humidity (see previous section
under Specifications). Do not place objects on top of the unit. Do not
obstruct any vents at the sides of the unit. Do not position the hub near
any heating source such as heater, radiator, or direct exposure to sun.
Prevent entering of water and moisture into the unit. If necessary, use
dehumidifier to reduce humidity.

2. Connecting to network devices

Connect one end of the network cable to any of the RJ45 ports on the
front panel, and connect the other end of the network cable to the RJ45
port of the network device. The network cables must comply with
EIA/TIA 568 specifications and Category 5 standard for 100Mbps data
rate or minimum Category 3 for 10Mbps data rate. Maximum length
between the hub and any network devices is 100 meters (300ft). Once
the network cable is connected on both ends and the attached network
devices are powered on, the green Link Status LED should be lit. If the
connected network devices are running at 100Mbps, the green Speed
LED (100M) should also be lit.

3. Uplink to Another Hub

Use the uplink port (the last port) to connect to another hub as illustrated
in Figure 5-2. Connecting cable must comply with EIA/TIA 568
specifications and Category 5 (100Mbps) standards to connect the hubs.
The Uplink port of the Dual-Speed hub supports Auto-Sensing function
which will automatically sense the speed of the connected hub and
operates at either 100Mbps or 10Mbps speed. If the connected hub is
another Dual-Speed hub or 100Base-TX hub, the transmission speed
between the two hubs will be set at 100Mbps and the green Speed (100M)
LED should be lit. The maximum length of the cable should not exceed 5
meters (15ft) when connecting two hubs running at 100Mbps and 100
meters (300ft) when connecting two hubs running at 10Mbps.

Figure 5-1 Connect the hub and network device

Dual Speed Hub

10/100 FAST ETHERNET CARD

FCC ID :

RTL8139

100m

Category 5

EIA/TIA 568

UTP Cable

Network
Adapter

10/100 FAST ETHERNET CARD

FCC ID :

RTL8139

10/100 FAST ETHERNET CARD

FCC ID :

RTL8139

100m

Category 5

EIA/TIA 568

UTP Cable

Network
Adapter

LNK
ACT

100M

1

2

3

4

5

6

7

8

9

10

11 12

13 14 15 16 17 18 19 20

21 22 23 24

LNK
ACT

100M

10M
COL

50+

30

10

5

1

UTIL

%

50+

30

10

5

1

UTIL

%

100M
COL

Power

Switch

24-Port

10/100Mbps

Dual Speed
Stackable Ethernet Hub

1

2

3

4

1

2

3

4

13

14

15

16

5

6

7

8

17

18

19

20

17

18

19

20

9

10

11

12

21

22

23

24

21

22

23

24

Uplink

9

Advertising
This manual is related to the following products: