Nokta detectors Golden Sense Quick Guide User Manual

Quick guide

Advertising
background image

QUICK GUIDE

GROUND BALANCE

Rotate the
sensitivity knob

to maximum
and the ground

balance knob to

the mid-level.

If the detector emits false signals due to interference,
reduce the sensitivity until the signals go away and

start searching.

Sensitivity is also the depth setting for the device.
Therefore, it is recommended that you do not lower it

too much suddenly but gradually decrease it to
determine the level where you are not getting any

interference and continue searching.

Holding the search coil 5cm.
above the ground, sweep it

right and left.

Turn on the device
by setting the

search mode knob

to ALL METAL.

Approximately 20

seconds later, the LEDs

on the handle will go off

and you will hear a tone

indicating that the device

is ready to use.

When the device detects a metal, it will produce an audible tone. For pinpointing the exact location of the target, move the search coil

over the target with short and faster/slower sweeps.

The most important thing to pay attention here is that as the ground balance goes into the right area, the device will start losing depth

for some non-ferrous metals except for gold. When the ground balance setting reaches the maximum point the device will detect iron
and gold but it will not detect some non-ferrous metals.

3) RIGHT AREA: Is used to eliminate high mineralized rocks and soils. If you are on a highly mineralized ground and the device is still getting

ground noise with the ground balance set at mid-level, turn the ground balance knob to the right in very small increments to eliminate the
noise.

Golden Sense ground balance setting consists of 3 different levels:

1) MID-LEVEL: Offers the most ideal and stable detection capability on different types of
grounds without sacrificing depth.

2) LEFT AREA: Recommended for more precise detections and for experienced users.
The device may generate false signals in changing ground conditions, even over holes

dug for testing. Therefore, if you set the ground balance in this area, you have to take

this factor into consideration.

After the ground balance and
sensitivity settings are

adjusted, you can start
searching by lifting the search
coil 5cm. above the ground and
sweeping it right and left,
keeping it parallel to the

ground.

To avoid missing smaller and
deeper targets, sweep the
search coil both from right to
left and left to right over each

area you are scanning, slightly
overlapping the sweeps as you
move forward.

GROUND BALANCE

2) LEFT AREA

3) RIGHT AREA

1) RECOMMENDED SETTING

MID-LEVEL

SENSITIVITY

SENSITIVITY

TURNING ON THE DEVICE

SENSITIVITY SETTING

1

2

SEARCHING AND METAL DETECTION

3

Advertising