P n e u C a l I I I

The 2500T offers
simplistic set-up to
make your job
easier.

The Altek PneuCal III is a highly accurate, digital calibrator for pneumatic field

instrumentation, including valve actuators, P/I transmitters, controllers, gauges,

switches and recorders. It is especially suitable for checking 3 to 15 PSI

systems. Its dual precision regulators enable output of set and variable

pressures to control devices, while the switching manifold allows fast selection

among the pressure ports. The unit simultaneously displays pressure and mA,

and has a built-in loop power supply. Accuracy is ± 0.035% of full scale for

all ranges. Optional external sensors measure other pressure ranges.

Each Unit Includes: Built-In Switch Testing, AC Adapter/Charger, Test Leads,
Hard Shell Carrying Case, Instructions, Built-in Pressure and Vacuum Pumps.

663 PNEUMATIC CALIBRATOR SPECIFICATIONS

Features:

Two Built-In Pumps –
Vacuum and Pressure

High Accuracy – 0.035% FS

1-51 mA Inputs

Switch Test Inputs

100 PSID Internal Sensor

Read up to 10,000 PSI With
Optional External Sensor

Built-In 24 VDC Loop Power

Temperature Compensated
From -10˚ to 50˚C
(13˚ to 122˚F)

Selectable Engineering Units

Just 18 Pounds

Dual Digital Display –
PSI and mA

Gauge, Differential, or
Vacuum Modes

Unless otherwise indicated, all specifications are referred to an ambient temperature of
23˚C ±1˚C (72˚F ±2˚F).

Pressure Ranges/Resolution: -5.00 to 100.00 PSI, -34.47 to 680.00 kPa, VAC to

10,000 PSI with optional modules

Pressure Accuracy:

±0.035% FS PSI (over -10 to +50˚C range)

Pressure Engineering Units:

PSI; Pa; kPa; MPa; BAR; mBAR; atm; kgf/cm

2

; mm Hg;

in Hg @ 0˚C and 15˚C, in H

2

O: 4˚C,15˚C, 20˚C, 23˚C; mm

H

2

0 @ 4˚C and 23˚C; cm H

2

O @ 4˚C and 23˚C

Electrical Engineering Units: mA; % of 4-20 mA; % of 10-50 mA
Electrical Input Connections: Double insulated, full-size banana jacks
mA Input Range:

1-51 mA

mA Resolution:

0.001mA

mA Accuracy:

±0.01% FS

Temperature Effect:

0.005%/˚C (mA Input only)

Loop Power:

24 VDC, ±20%, 25 mA max. (When loop power is enabled,
the discharge rate on the batteries exceeds the charging
capacity of the 16 VDC adapter.)

Switch Test:

Dry contacts only. (Display will freeze when switch test inputs
change state. Press RESET key to resume normal operation.)

Operating Temperature:

-10˚C to 50˚C (13˚F to 122˚F)

Storage Temperature:

-30˚C to 85˚C (-22˚F to 185˚F)

Zero Adjustment:

Via front panel push-button (pressure only)

Display:

2-line,16 character alpha-numeric display

Power:

Internal Ni-Cd batteries or 16 VDC adapter. (To charge battery
the unit has to be powered off.)

Battery Life (typical):

23 hrs. (1 hr. with 24 VDC transmitter power at 20 mA)

Dimensions (h x w x d):

7"x18.5"x15.5"

P H O N E : 1 - 8 0 0 - 3 2 2 - 5 8 3 5 • F A X : 7 1 6 - 3 4 9 - 3 5 1 0

E - M A I L : a l t e k s a l e s @ a l t e k c a l i b r a t o r s . c o m • W E B : w w w. a l t e k c a l i b r a t o r s . c o m