Robinair 34970 User Manual

R-12, R-134, Warning

Advertising
background image

114614 (Rev. C, April 8, 2014)

© Bosch Automotive Service Solutions LLC

WARNING

When working with high pressure air sup plies and

refrigerants, wear goggles to reduce the hazards

of flying particles and contact with refrigerants.

The Air-Vac is a venturi-type vacuum pump powered by
compressed air and designed for mobile air conditioning
service.
Operating Notes
A constant air source of 75 psi is required for pump
operation. The pump has an air consumption of
4.2 SCFM and will pull a vacuum up to 29.7 inches of
mercury at sea level.
Oil or water in the air line will not harm the pump; it
will be exhausted through the pump.

Connecting the Pump
1. Connect a constant (75 psi) air source to the air

input fitting located on the back of the pump. This
fitting is a standard

1

/

4

in. N.P.T.F.

Note: Use a quick-disconnect fitting on the air input
fitting for fast, easy connections to the air supply.
2. Connect the center hose from a manifold gauge set,

which is connected to the A/C system, to the vacuum
tee fitting (appropriate for the type of system —
R-12 or R-134a) on the front of the pump. Tightly
cap the port not used. Open both valves on the
manifold.

3. Turn on the air supply to evacuate the system.

Follow the vehicle manufacturer’s specifications for
correct evacuation.

4. Turn off the air supply before disconnecting the

hose from the vacuum fitting.

Model No. 34970

A

ir

-V

Ac

for

r-12

And

r-134

A

Because of ongoing product improvements,

we reserve the right to change

design, specifications, or materials without notice.

655 Eisenhower Drive

Owatonna, MN 55060 USA

Technical Services: 1-800-822-5561

Fax: 1-866-259-1241

Customer Service: 1-800-533-6127

Fax: 1-800-283-8665

www.robinair. com