PSM80BA10

Power Semiconductor Half-Bridge Module

Package

Schematic Symbol

PSM80BA10

Power Semiconductor Half-Bridge Module

Data Sheet (Rev 01- 05/28/09)

Description
This module contains 4 Solidtron (CCS) Size 12 SGTOs
and 4 Size 12 S-Diodes, packaged for use in a solid
state current limiter or similar applications. This
module provides connections for the AC input and
output bus. The module includes an electrically
conductive base-plate. The module is typically used
at 60Hz.
The gate drive for the SGTOs are integrated into the
module and is powered by an external isolated 15V
DC supply.
The current controlled Solidtron (CCS) SGTO is an n-
type Thyristor in a high performance ThinPak

TM

package. The device gate is similar to that found on a
traditional GTO Thyristor. The CCS features the high
peak current capability and low On-state voltage drop
common to SCR thyristors combined with high dI/dt
capability.

Application Specific Operating Conditions

SYMBOL

VALUE

UNITS

Peak Off-State Voltage (60Hz, 3 pulse)

VDRM

4

kV

Off-State Rate of Change of Voltage Immunity

dv/dt

1

kV/uSec

Repetitive Peak Anode Current (Pulse Width=30 uSec)

IASM

15

kA

Gate Assisted Turn-off

tqq

< 15

uSec

Operating Junction Temperature

TJO

125

oC

Maximum Junction Temperature

TJM

140

oC

I2t for 8.3 ms, half-sine wave, Ipeak = 4kA

I2t

A2s

Anode-Cathode On-State Voltage at Tj = 140 C,

VT

1.2

V

This SILICON POWER product is protected by one or more of the following U.S. Patents:

CAO 05/28/09

5,446,316
5,557,656
5,564,226
5,517,058
4,814,283

5,521,436
5,585,310
5,248,901
5,366,932
5,497,013

5,105,536
5,777,346
5,446,316
5,577,656
5,473,193

5,209,390
5,139,972
5,103,290
5,028,987
5,304,847

4,958,211
5,111,268
5,260,590
5,350,935
5,640,300

5,206,186
5,757,036
5,777,346
5,995,349
4,801,985

4,857,983
4,888,627
4,912,541
5,424,563
5,399,892

5,082,795
4,980,741
4,941,026
4,927,772
4,739,387

4,644,637
4,374,389
4,750,666
4,429,011
5,293,070

Application Specific Operating Conditions

For Each Module:

• Frequency = 60 Hz
• Blocking Voltage (peak) = 4 kV
• Current (rms) = 700A, 50% duty cycle

Features

• Low On-State Voltage
• Low trigger current
• Low Inductance Package

Module Operating Characteristics