SKC 223-441 Take Charge 5 Li-Ion Battery Charger User Manual

Operating instructions

Advertising
background image

Take Charge 5 Li-Ion Battery Charger for

AirChek XR5000 and Leland Legacy Sample Pumps

Cat. No. 223-441

The compact, lightweight SKC Take Charge 5 is designed for optimal charging of
lithium-ion (Li-Ion) batt ery packs used to power high-power and standard model
SKC AirChek

®

XR5000 sample pumps and the Leland Legacy

®

sample pump.

Charge up to fi ve Li-Ion batt ery packs simultaneously.

Performance Profi le

Dimensions:

2.4 x 9.2 x 5.25 in (6.1 x 23.4 x 13.3 cm)

Weight:

1.3 lbs (0.59 kg)

Charging Time:

High-power AirChek XR5000: 8 hrs

Standard AirChek XR5000: 4 hrs

Leland

Legacy:

15 hrs

Operating Temperature:

14 to 140 F (-10 to 60 C)

Status LED:

Green = Connected pump is fully charged or no

pump is connected.

Red = Connected pump is charging.

Input Voltage:

100-240 V AC

Power Cord:

SVT Type, 3 x 18 AWG, 300 V, VW-1, 60 C,
1.5 m maximum length

Compatible Batt ery Packs: Leland Legacy Li-Ion (P75692),

AirChek XR5000 High-power Li-Ion (P85004), and
AirChek XR5000 Standard Li-Ion (P85002)

Intrinsic Safety:

Not intended for use in hazardous locations

Operating Instructions

863 Valley View Road, Eighty Four, PA 15330 USA

Tel: 724-941-9701 Fax: 724-941-1369 e-mail: [email protected]

(Typical charging times
vary with pump model,
batt ery capacity, and level of
discharge.)

Operation

1. Plug power cable into jack on

back of unit.

2. Insert power plug into

standard (100-240 volt) wall
outlet.

3. Insert charging plug on front

of unit into pump charging
jack (see right for location of
charging jack)
. Repeat this step
for the remaining 4 ports if
desired. Ports may contain the
same or any combination of
the compatible batt ery packs
listed in the Performance
Profi le on the reverse side.

The LED at each port will display green until a pump is att ached to the

charging

plug.

4. Charge pump batt ery pack(s). The LED(s) will display red while charging.

The LED(s) will display green when batt ery pack(s) is fully charged.

Note

Completely charge batt ery for optimum results.

5. Remove charging plug(s) from pump charging jack(s) when batt ery pack(s) is

fully charged.

• Do not use in hazardous locations, in rain, or in standing water. For

indoor use only

• Do not obstruct the cooling fan vent or air intakes.

• Use only a 1.6-amp, 250-volt replacement fuse.

Caution

AirChek XR5000

Model 210-5000

Serial No. 00000

SKC Inc., Eighty Four

, P
A

15330

Li-Ion Battery Pack P85002

7.4V, 2.2Ah, 16.3Wh

Use only SKC

specified chargers.

U.S. DOT Restrictions may apply.

See Operating Instructions.

SKC Inc.

www.skcinc.com

Five-station Li-Ion Battery Charger for

SKC AirChek

®

XR5000 and Leland Legacy

®

Sample Pumps

LED Green: Connected pump is fully charged or no pump connected
LED Red: Connected pump is charging

SN: 12345

SKC Inc., Eighty Four, PA 15330 U.S.A.

www.skcinc.com

www.skcinc.com

Form 37050 Rev 1403

Top of Leland Legacy

Sample Pump

Back of AirChek XR5000

Sample Pump

Charging

jack

Charging

jack

Jack

For additional pump charging information, see pump operating instructions
for the AirChek XR5000 at www.skcinc.com/instructions/38047.pdf and for the
Leland Legacy at www.skcinc.com/instructions/40075.pdf.

Note

SKC Limited Warranty and Return Policy

SKC products are subject to the SKC Limited Warranty and Return Policy, which
provides SKC’s sole liability and the buyer’s exclusive remedy. To view the com-
plete SKC Limited Warranty and Return Policy, go to htt p://www.skcinc.com/
warranty.asp.