3.5.7

DANGER

Grounding - An improper or insufficient ground connection creates an electrical

shock hazard when touching any part of the hoist or trolley. In the Power Supply Cable the ground wire
will be either Green with Yellow stripe or solid Green. It should always be connected to a suitable
ground connection. Do not paint the trolley wheel running surfaces of the beam as this can affect
grounding.

3.6 Preoperational

Checks and Trial Operation

3.6.1

WARNING

Confirm the adequacy of the rated capacity for all slings, chains, wire ropes and all

other lifting attachments before use. Inspect all load suspension members for damage prior to use and
replace or repair all damaged parts.

3.6.2

WARNING

Verify and correct all chain irregularities prior to operating the hoist. Refer to

Section 3.2

.

3.6.3

Measure and record the “k” dimension of all hooks on hoist. See

Table 5-4

under

Section 5

,

“Inspection”.

3.6.4

Record the hoist's Code, Lot and Serial Number (from the name plate on the hoist; see section 10) in
the space provided on the cover of this manual.

3.6.5

Ensure that the hoist is properly installed to either a fixed point, or trolley, whichever applies.

3.6.6

If hoist is installed on a trolley, ensure that

„

trolley is properly installed on the beam, and

„

stops for the trolley are correctly positioned and securely installed on the beam.

3.6.7

Ensure that all nuts, bolts and split pins (cotter pins) are sufficiently fastened.

3.6.8

Pull down on the Pendant and ensure that the Cord Strain Relief Cable takes the force, not the
Pendant Cord.

3.6.9

CAUTION

Check supply voltage before everyday use. If the voltage varies more than 10% of

the rated value, electrical devices may not function normally.

3.6.10 Confirm proper operation.

„

Before operating read and become familiar with

Section 4

- Operation.

„

Before operating ensure that the hoist (and trolley) meets the Inspection, Testing and Maintenance
requirements of ANSI/ASME B30.16.

„

Before operating ensure that nothing will interfere with the full range of the hoist’s (and trolley’s)
operation.

3.6.11

WARNING

The hoist must be connected to the power source such that its direction of

operation corresponds to the up-and-down commands issued from the pendant control; i.e. pushing the
up button must cause the hoist to raise. If the hoist does not operate correctly, shut off and lockout
/tagout the main power source to the hoist. Disconnect and switch any two of the three input power
leads at the power source to correct the hoist’s motor phasing.