LiftMaster TAC2C Single Tenant Telephone Access Control Retrofit System User Manual

Installation guide, Tac2c, Introduction 4

Advertising
background image

COLOR LABEL

DESCRIPTION

POWER

16 Volt DC power input

AUTOCALL

Input for accessory device to

trigger home dialing

PHONE/TELCO

Input connection for TELCO

RELAY 2, NO

NO input for Relay 2

RELAY 2, NC

NC input for Relay 2

RELAY 2, COM

COM input for Relay 2

RELAY 1, NO

NO input for Relay 1

RELAY 1, NC

NC input for Relay 1

RELAY 1, COM

COM input for Relay 1

2

1

Unplug the transformer from the outlet. Disconnect the
wires from the existing transformer.

Remove the screws from the Crown Jewel faceplate
using the provided hex tool.

Slide the faceplate forward and rotate downward.

Identify the terminal blocks on the Crown Jewel board. Attach the provided labels to the
corresponding wires as shown. Once the wires are labeled, remove them from the board.

SPECIFICATIONS

Power Supply: 16 Vdc 2.5 Amp

The 110 Vac outlet must be dedicated to the unit only. This outlet
should be wired back to its own 10 Amp minimum circuit breaker.
This will prevent two problems:

• Other equipment cannot introduce spikes, noise, surges, or dips

into the power circuit.

• The unit’s operation will not be affected if any other equipment

develops a short circuit across the power line.

Hardware Bag
Complete with: Hex Head Tamper Resistant Screws (4), Hex Tool (1),
and Ground Lug (1)

Faceplate with Processor Board (1)

16 Volt DC 2.5 Amp Transformer (UL Listed) (1)

Install and Programming Guide (1)

Labels (9)

CARTON INVENTORY

Introduction

4

POWER

EXTERNAL KEYPAD

(no longer available)

RELAY 1

RELAY 2

DO NOT run data wires and HIGH VOLTAGE wires in the same
conduit. The HIGH VOLTAGE wires may interfere with the data
wires and cause the unit to malfunction.
To AVOID damaging gas, power or other underground utility lines,
contact underground utility locating companies BEFORE digging.
To prevent damage to the unit:
• Use the new 16 Vdc transformer ONLY.
• Use dedicated 110 Vac outlet ONLY.

Installation Guide

TAC2C

TAC1 RETROFIT KIT FOR CROWN JEWEL SYSTEMS

Autocall

Terminal

Block

Exit Terminal Block

(no longer available)

Separate the Exit terminal block

from the Autocall terminal block by

sliding them apart as shown.

AUTOCALL

EXIT

(no longer available)

PHONE/TELCO

When the wires have

been labeled correctly,

remove the terminal

blocks from the board.

RELAY 1, COM

RELAY 1, NC

RELAY 1, NO

RELAY 2, COM

RELAY 2, NC

RELAY 2, NO

The relay wires will need to be

removed and re-wired to the terminal

block on the new board.

5

Remove the screws (2) securing the faceplate to the
housing.

Ground Wire

Remove the ground wire
that runs from the board

to the ground screw in

the existing housing.

1

2 3

4

5 6

7 8

9

*

0

#

6.22"

Keypad

Speaker

Call Button

9.72"

Dimensions: 9.72" x 6.22" (W x H)

CROWN JEWEL BOARD

IMPORTANT: The TAC2C has a Ringer Equivalence Number (REN) of 5 with or without a TELCO line.

3

Microphone

IMPORTANT NOTE: DO NOT use the existing transformer, the
provided transformer MUST be used instead.