LockeyUSA TB-LINX Kit User Manual

Tb-linx kit instructions

Advertising
background image

The TB-LINX Kit is intended to adapt your TB200/400/600
or TB250+/450+/650+ Hydraulic Gate Closer to fence posts
3-inches or smaller. The TB-LINX kit comes with a 3” U-
Bolt to fit to a 2 7/8” post.

If the post is smaller than 3-inches, a smaller U-Bolt must
be used to match the post size.

IMPORTANT:
TB200/400/600 and TB250+/450+/650+ Gate Closers will
not work with Bulldog Style hinges. You MUST use a
center pin/pivot type hinges or Male/Female style with
center pivot pin.

TO INSTALL:

1. Mount the Triangular Mounting Bracket to the flat-

side of the Post-Mount Collar using the two (2) 1/4” x
1” bolts and securing with two (2) 1/4" Lock Nuts.

2. Place collar to the OPEN side of POST and attach with

3 x 4 ½” U-BOLT and secure with two 3/8” Lock Nuts.
The gate must swing towards the Triangular Bracket
and the Triangular Bracket should be on a 90 degree
angle from gate.

3. You are now ready to mount the Gate Closer. Use

the 2 self-tapping screws to fit Gate Bracket to gate.
(REFER TO GATE CLOSER INSTRUCTIONS)

IMPORTANT: BEFORE INSTALLATION OF THE CLOSER IT IS IMPORTANT TO MEASURE THE DISTANCE FROM THE TRIANGULAR
BRACKET TO GATE BRACKET IN THE 90-DEGREE OPEN POSITION. THE DISTANCE MUST NOT BE LESS THAN 22”. IF LESS THAN
22”, THE GATE CLOSER MAY HYPER-COMPRESS AND VOID THE WARRANTY.

IN MOST CASES, HOLES 3 & 4 ON THE TRIANGULAR BRACKET (HOLES FURTHEST FROM THE POST), WILL NOT CREATE
SUFFICIENT DISTANCE (22”) BETWEEN THE TRIANGULAR BRACKET AND GATE BRACKET.

Part Name

Qty.

Triangular Mounting Bracket (included w/ Gate Closer)

1

Gate Bracket (included w/ Gate Closer)

1

Post-Mount Collar

1

U-Bolt – 3 x 4 ½

1

Lock-Nuts – 3/8

2

Lock-Nuts – 1/4

2

Bolts 1/4 x 1

2

Self-Tapping Screws

2

TB-LINX Kit
Instructions