AMD Geode™ LX Processors Data Book

331

Display Controller Register Descriptions

33234H

6.6.5.5

DC CRT Vertical Blank Timing (DC_V_BLANK_TIMING)

This register contains vertical blank timing information. All values are specified in lines. For interlaced display, no border is
supported, so blank timing is implied by the total/active timing.

6.6.5.6

DC CRT Vertical Sync Timing (DC_V_SYNC_TIMING)

This register contains CRT vertical sync timing information. All values are specified in lines.

DC Memory Offset 054h
Type

R/W

Reset Value

xxxxxxxxh

DC_V_BLANK_TIMING Register Map

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

RSVD

V_BLANK_END

RSVD

V_BLANK_START

DC_V_BLANK_TIMING Bit Descriptions

Bit

Name

Description

31:27

RSVD

Reserved. These bits should be programmed to zero.

26:16

V_BLANK_END

Vertical Blank End. This field represents the line at which the vertical blanking signal
becomes inactive minus 1. If the display is interlaced, no border is supported, so this
value should be identical to V_TOTAL.

15:11

RSVD

Reserved. These bits should be programmed to zero.

10:0

V_BLANK_

START

Vertical Blank Start. This field represents the line at which the vertical blanking signal
becomes active minus 1. If the display is interlaced, this value should be programmed to
V_ACTIVE plus 1.

DC Memory Offset 058h
Type

R/W

Reset Value

xxxxxxxxh

DC_V_SYNC_TIMING Register Map

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10

9

8

7

6

5

4

3

2

1

0

RSVD

V_SYNC_END

RSVD

V_SYNC_START

DC_V_SYNC_TIMING Bit Descriptions

Bit

Name

Description

31:27

RSVD

Reserved. These bits should be programmed to zero.

26:16

V_SYNC_END

Vertical Sync End. This field represents the line at which the CRT vertical sync signal
becomes inactive minus 1.

15:11

RSVD

Reserved. These bits should be programmed to zero.

10:0

V_SYNC_

START

Vertical Sync Start. This field represents the line at which the CRT vertical sync signal
becomes active minus 1. For interlaced display, note that the vertical counter is incre-
mented twice during each line and since there are an odd number of lines, the vertical
sync pulse will trigger in the middle of a line for one field and at the end of a line for the