33234H

6.6.19.2 CRTC Data

6.6.19.3 Horizontal Total

6.6.19.4 Horizontal Display Enable End

6.6.19.5 Horizontal Blank Start

Data Address

3B5h or 3D5h

Type

R/W

Reset Value

00h

CRTC Data Register Bit Descriptions

Bit

Name

Description

7

RSVD

Reserved.

6:0

DATA

Data.

Index

00h

Type

R/W

Reset Value

00h

Horizontal Total Register Bit Descriptions

Bit

Name

Description

7:0

H_TOTAL

Horizontal Total. This value specifies the number of character clocks per horizontal
scan line minus 5. It determines the horizontal line rate/period.

Index

01h

Type

R/W

Reset Value

00h

Horizontal Display Enable End Register Bit Descriptions

Bit

Name

Description

7:0

H_DISP_END

Horizontal Display Enable End. This value specifies the number of displayed charac-
ters minus 1. It determines the width of the horizontal display enable signal.

Index

02h

Type

R/W

Reset Value

00h

Horizontal Blank Start Register Bit Descriptions

Bit

Name

Description

7:0

H_BLANK_ST

Horizontal Blank Start. This value specifies the character position on the line where the
horizontal blanking signal goes active.