AMD Geode™ LX Processors Data Book

Display Controller Register Descriptions

33234H

6.6.19.12 Maximum Scan Line

6.6.19.13 Cursor Start

6:5

BYPE_PAN

Byte Panning. This value causes the pixel data stream to be fetched zero, one, two, or
three character positions early for use with pel panning in the attribute controller. This
field is used when the video serializers are chained together (by two or by four).

4:0

ROW_SCAN

Starting Row Scan. This specifies the value loaded into the row scan counter on the first
text line of the screen. Changing this value in text modes allows the screen to be scrolled
on a scan line basis rather than a text line basis. The starting row scan count for all sub-
sequent scan lines is 0.

Index

09h

Type

R/W

Reset Value

00h

Preset Row Scan Register Bit Descriptions

Bit

Name

Description

Maximum Scan Line Register Bit Descriptions

Bit

Name

Description

7

DBL_SCAN

Double Scan. When this bit is set to a 1, the row scan counter increments every other
scan line. When this bit is cleared to 0, the row scan counter increments on every scan
line. This bit is used to make 200 line text modes occupy 400 physical scan lines on the
screen.

6

LN_CMP9

Line Compare Register Bit 9. See LINE_COMP[7:0] bit description (Index 18h[7:0]).
LINE_COMP8 is located at Index 07h[4].

5

V_BLANK_ST9

Vertical Blank Start Register Bit 9. See V_BLANK_ST[7:0] bit description (Index
15h[7:0]). V_BLANK_ST8 is located at Index 09h[3]).

4:0

MAX_LINE

Maximum Scan Line. This field specifies the number of scan lines per character row
minus 1. The row scan counter will count up to this value then go to 0 for the next charac-
ter row.

Index

0Ah

Type

R/W

Reset Value

00h

Cursor Start Register Bit Descriptions

Bit

Name

Description

7:6

RSVD

Reserved.

5

CURS_OFF

Cursor Off. When set to 1, the cursor is turned off and will not appear on the screen.
When this bit is 0, the cursor is displayed. This bit is only applicable in text modes.

4:0

CURS_ST

Cursor Start. This field specifies the first scan line in the character box where the cursor
is displayed. If this value is greater than the Cursor End value (CURS_END, Index
0Bh[4:0]), then no cursor is displayed. If this value is equal to the CURS_END value,
then the cursor occupies a single scan line.