TIF 9020A Electronic Charging Scale User Manual

Tif9020a electronic scale, Specifications

Advertising
background image

Cylinder

Platform

LCD Readout

Features of the Scale

Expansion

Port

Control

Box

Keypad

NOTE: False readings may occur if the scale is used in environments having high

electrical noise. False readings may also occur if the cylinder touches the case or

controls, or if anything touches the platform, especially the cord to the control box.

TIF9020A Electronic Scale

SETUP

1. Place the unit on a firm and level surface.

2. Remove the control box from the case in order

to provide clearance.

3. Switch unit on by pushing the ON/OFF button.

4. Select the desired unit of measure by pressing

and releasing the UNITS button. Three scales

are available:

lbs./oz. (0 lbs. 0.0 oz.)

decimal pounds (0.000 lbs.)

kilograms (0.000 kg)

OPERATION

1. Carefully place refrigerant cylinder in center of

the platform.

2. Connect refrigerant cylinder to a charging mani-

fold via utility hose if charging refrigerant, or to

a recovery machine if recovering refrigerant.

3. Open refrigerant tank valve. Purge air from hoses.

4. Press ZERO button; display changes to zero.

5. Open manifold valve(s), or turn on recovery

unit. Refrigerant begins to flow, and display

indicates the weight being removed (if charg-

ing) or added (if recovering). A minus sign (-)

appears if weight is being removed.

6. Monitor the display; when desired charge or

maximum allowable fill is reached, close the

cylinder valve and manifold valves, and/or

switch off the recovery unit.

7. When operation is complete, turn unit off by

pushing the ON/OFF button. Close cylinder

valve, disconnect hose(s), and store the unit.

LOW RESOLUTION MODE

In normal operating mode, the high resolution of the

scale may lead to noticeable fluctuations in the read-

ing caused by weight shifts or wind. To improve this

situation, a low resolution mode may be activated.

1. With scale switched on, with any unit or weight

displayed, press and hold the UNITS button.

2. The enunciators (units of measure) will begin to

flash.

3. Release the button and continue normal opera-

tion. Resolution is now reduced by a factor of 5

(1.0 oz./.050 lbs./20 g) and will provide stable

readings under extreme conditions.

4. To return to the normal resolution mode,

depress and hold the UNITS button until the

enunciators stop flashing.

WEIGHT MEASUREMENTS

The unit may be used strictly as a weight scale.

1. Follow steps 1 through 4 in Setup.

2. Press the ZERO button. Display changes to zero.

3. Carefully place the object (e.g., cylinder) that is to

be weighed directly in the center of the platform.

4. Gross weight will be displayed.

5. When weighing has been completed, turn unit off.

This feature is especially useful when recovering. To

calculate the amount of refrigerant in a tank, subtract

the "Tare" weight (marked on cylinder) from the dis-

played amount to find the quantity of refrigerant in

the cylinder.

OVER-RANGE INDICATION

If the gross weight applied to the platform exceeds

the specified range, the unit will display a single 1 at

the left of the display.

BATTERY INSTALLATION

The BATTERY enunciator will appear when the battery

needs replacing. A display of “---” indicates battery

voltage insufficient for operation. Replace battery in

order to resume operation.

1. Remove battery from control box by removing the

battery cover located on the back of the box.

2. Disconnect the battery from the battery clip.

3. Attach a new 9V alkaline battery to the clip.

4. Install new battery and cover.

SPECIFICATIONS

Range:

0 lbs. 0.0 oz. to 199 lbs. 15.8 oz.

0.000 lbs. to 199.990 lbs.

0.000 kg to 100.000 kg

Resolution:

Normal: 0.2 oz. / 0.010 lbs. / 4 g

Low:

1.0 oz. / 0.050 lbs. / 20 g

Accuracy:

± 0.5% of reading ± 1 digit

Power Supply: One 9V alkaline battery
Battery Life: 30 hrs. (approx.)
Operating
Temperature
: 32°F to 120°F

(0°C to 49°C)

Weight:

6.15 lbs. (2.79 kg)

Dimensions: 15.25 x 10.5 x 2.5"

(38.7 x 26.7 x 6.35 cm)

552154 rev B

DISPLAY INDICATORS

Warranty and Repair Policy

This instrument has been designed to

provide unlimited service. Should it

become inoperative after the user has

performed recommended maintenance, a

no-charge repair or replacement will be

made to the original purchaser. This applies

to all repairable units that have not been

damaged or tampered with. The claim must

be made within TWO years of date of

purchase.
An additional 90-day warranty period will

cover the repaired or replaced unit. If you

have questions or need technical

assistance, call toll-free to speak with a

Customer Service Representative:

(800) 327-5060.

655 Eisenhower Drive

Owatonna, MN 55060

Phone: (800) 327-5060

Fax: (866) 287-7222

www.tif.com

Designed and engineered in the USA.

Manufactured in China.