IMPORTANT SAFETY INSTRUCTIONS
• Read all instructions.
• Do not operate the flashlight if it has been damaged.
The OPTI-LUX 365 must be fully charged before first use.
CAUTION: Use only the battery charger packed with the flashlight.

Do not attempt to use the charger to recharge any other product.

• Use only the 127568 batteries (see Replacement Parts).
• The OPTI-LUX 365 is not approved for use in hazardous atmospheres.

Do not attempt to use it in areas requiring explosion-proof lighting.

• Never use this equipment in any manner not specified in these instructions because

your protection may be impaired.

CHARGING AND USE

The OPTI-LUX 365 flashlight comes equipped with a battery charger

available in several different voltages. See Replacement Parts.
Fully charge both batteries before first use.
• Place the batteries in the battery charger cradle. The light on each battery charger will

show green when charged, and red when the battery is low. A full charge for two batteries
will take approximately four hours.

• Turn the knob on the bottom of the flashlight to open the battery compartment. Insert

one Li-on battery, positive end down, and close the compartment. The second charged
battery will serve as backup.

• The flashlight will operate for up to four hours on a fully charged battery.
• Press the switch to light and use the OPTI-LUX 365.
CARE AND USE OF LITHIUM-ION (Li-ion) BATTERIES
• Do not allow Li-ion batteries to fully discharge frequently, since this will put a strain

on the batteries. They will work more efficiently on multiple partial discharges through
regular use (every 2-3 weeks), and frequent recharges.

• The batteries may be left in the battery cradle after charging. The charger automatically

cuts the charge when the charge is full.

• Remove the battery from the lamp and store it separately. Before prolonged storage

(30 days or more), charge the battery for at least two hours. Store
partially charged for best results.

• Store in a fairly cool environment away from sunlight, heat and humidity. Store the

battery at temperatures between 5 °C and 20 °C (41 °F and 68 °F).
NOTE: The battery self-discharges during storage. Higher temperatures (above 20 °C
or 68 °F) will reduce the battery storage life.

• Lithium-Ion batteries are subject to disposal and recycling regulations that vary by

country and region. Always check and follow your applicable regulations before
disposing of any battery.

WARNING: Be sure to use genuine OPTI-LUX 365 replacement parts.
Using another manufacturer's replacement parts could affect product
performance and will void the warranty.

LEAK DETECTION
1. Turn off the engine.
2. Add fluorescent dye to the system. For best results, use super-bright Tracerline

®

Fluoro-Lite

®

and Dye-Lite

®

dyes. See instructions included with dyes.

3. Start the engine and run the system for 5 to 10 minutes to circulate the dye.
4. Turn off the engine. Put on the glasses supplied. Scan the system with the lamp.

Leaks will show with a bright fluorescent glow. Use the lamp in low-light conditions for
best performance.

5. Do not look directly into the light. Wearing the UV-aborbing glasses supplied with the

lamp will make leaks clearly visible.

6. After the leaks are repaired, clean the remaining dye from the leak sites with

Tracerline

®

GLO-AWAY™ dye cleaner or a shop solvent.

7. Reinspect with the OPTI-LUX 365 to be sure all dye residue has been removed.

Residual dye could give a false leak indication.

8. Run the engine for another 5 to 10 minutes and reinspect with the OPTI-LUX 365. No

glow means that all leaks have been repaired.

English

DANGER

Ultraviolet radiation emitted from this product. Avoid exposure. ALWAYS

WEAR PROTECTIVE CLOTHING. EXPOSURE MAY CAUSE PREMATURE

AGING OF THE SKIN AND CANCER. ALWAYS WEAR PROTECTIVE EYEWEAR;

FAILURE TO DO SO MAY RESULT IN SEVERE BURNS OR LONG TERM INJURY

TO EYE. Never look directly into the lamp. Exposure can cause eye and skin

allergy and allergic reactions. Medications or cosmetics may increase your

sensitivity to ultraviolet radiation. Consult physician before operating this

product if you are using medications or have a history of skin problems or

believe yourself especially sensitive to sunlight.

FOR PROFESSIONAL EXAMINATION USE ONLY

OPTI-LUX™ 365

Pure UV LED Leak Detection Flashlight

Parte No. TP-8691

IMPORTANT SAFETY INSTRUCTIONS

Do not look directly into the light. Wear the UV-absorbing protective glasses

provided. Use in low-light conditions to achieve the best leak detection results.

For best results, use super-bright Tracerline

®

fluorescent dyes for A/C

and fluid systems.

IMPORTANT:

Fluorescent Dyes Required!

(1,1) -2- TP-8691 OPTI-LUX 365 (AM12008-7).indd 9/19/2013 4:20:58 PM