EMC Specifications

19

*XLGDQFH DQG 0DQXIDFWXUHU¶V 'HFODUDWLRQ  (OHFWURPDJQHWLF ,PPXQLW\ 1RQ/LIH

6XSSRUWLQJ (TXLSPHQW

The ZOLL Base PowerCharger

1x1

is intended for use in the electromagnetic environment specified below. The customer or

the user of the ZOLL Base PowerCharger

1x1

should ensure that it is used in such an environment.

Immunity test

IEC 60601 test level

Compliance level

Electromagnetic environment - guidance

Portable and mobile RF communications
equipment, including cables, should be used no
closer to any part of the

=2// %DVH

3RZHU&KDUJHU

[

than the recommended

separation distance calculated from the equation
applicable to the frequency of the transmitter.

Recommended separation distance

Conducted RF
IEC 61000-4-6

3 Vrms
150 kHz to 80 MHz

3 Vrms

d=

Radiated RF
IEC 61000-4-3

3 V/m
80 MHz to 2.5 GHz

3 V/m

d=

80 MHz to 800 MHz

d=

800 MHz to 2.5 GHz

where P is the maximum output power rating of
the transmitter in watts (W) according to the
transmitter manufacturer and d is the
recommended separation distance in
metres (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey,

a

should be less than the compliance level in each
frequency range.

b

Interference may occur in the vicinity of
equipment marked with the following symbol:

1RWH  $W  0+] DQG  0+] WKH KLJKHU IUHTXHQF\ UDQJH DSSOLHV
1RWH  7KHVH JXLGHOLQHV PD\ QRW DSSO\ LQ DOO VLWXDWLRQV (OHFWURPDJQHWLF SURSDJDWLRQ LV DIIHFWHG E\ DEVRUSWLRQ DQG

UHIOHFWLRQ IURP VWUXFWXUHV REMHFWV DQG SHRSOH

a

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile

radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the ZOLL Base PowerCharger

1x1

is used exceeds the

applicable RF compliance level above, the ZOLL Base PowerCharger

1x1

should be observed to verify normal operation. If

abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the ZOLL
Base PowerCharger

1x1

.

b

Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [V

1

] V/m.

1.17 P

1.17 P

2.33 P